Safety
Version 1.1.3 - 2020-07-21
9
Translation of the original instructions
B34H | B34HV
GB
B34H_B
34HV_
GB_
1
.f
m
1.4
Reasonably foreseeable misuses
Any other use as the one determined under the "Intended use" or any use beyond the descri-
bed use shall be deemed as not in conformity and is forbidden.
Any other use has to be discussed with the manufacturer.
It is only allowed to process metal, cold and non-inflammable materials with the geared drill.
In order to avoid misuses it is necessary to read and understand the operating instructions
before the first commissioning.
The operators must be qualified.
INFORMATION
The drilling machine B34HV for regulating the speed is built according to the standard EN
61800-3 class C2.
WARNING!
This machine is not intended for use in residential buildings, in which the power supply
is provided via a public low voltage supply system. In these areas it may possibly be
difficult to guarantee electromagnetic compatibility due to lead bound as well as emitted
interferences.
Overview of the EMC categories:
Categorie C1
required limit values Class B Group 1 according to EN 55011
Categorie C2
Required limit values class A Group 1 according to EN 55011, Installation by EMC experts
and warning: “This is a product of category C2 according to EN 61800-3. This product may
cause radio interference in a residential area. In this case, it may be necessary for the ope-
rator to take appropriate action.“
Categorie C3
Required limit values class A group 2 according to EN 55011, whereby these limit values
are below those of class A group 1, plus warning: „This type is not suitable for connection to
a public low-voltage network supplying residential buildings. When connecting to a public
low voltage network, radio frequency interference is expected. "
Machine B34HV
Categorie
C1
C2
C3
C4
Environment
Residential area
Business area
Industrial area
Industrial area
Voltage / Current
< 1000 V
> 1000 V
EMC knowledge
no requirement
Installation and commissioning by an EMC expert