background image

 

OPTICAL SYSTEMS DESIGN 

 

DOC ID: 10108502 

OSD159 OPERATOR MANUAL

 

 

PAGE 8  

 

2

 

INSTALLATION AND OPERATION 

2.1

 

INTRODUCTION 

This section outlines the methods required to install and operate the OSD159 successfully. It should be 
studied carefully if damage to the equipment or poor results are to be avoided. 
This equipment has been fully tested prior to dispatch and is ready for immediate operation.  However it 
is advisable to check for external transportation damage before operation. If damage is evident, return 
the unit with the packaging to your supplier immediately. 

2.2

 

INSTALLATION 

2.2.1

 

WARNING AND PRECAUTIONS 

ELECTROMAGNETIC COMPATIBILITY 

 

WARNING

: This is a 

Class A product

. In a domestic environment this product may cause radio 

interference in which case the user may be required to take adequate measures. 
 

OPTICAL OUTPUT OPERATION

 

 

Class 1 

Class 3A 

The multimode version of the OSD159 is a 

Class 1 LED product

. Wavelength of 850nm 

and <-8dBm power output. 

The singlemode versions of the OSD159 are 

Class 3A

 

laser products.

  Wavelength of 

1310nm and <+5dBm power output or 
wavelength of 1550nm and <+7dBm power 
output. 

 

 

 

PRECAUTIONS 

 

 

All service personnel should be provided training as to the hazards of direct viewing of laser 
radiation and of the precautionary measures during servicing of equipment 

 

Areas where laser products are installed should be restricted in access to trained service 
personnel only and appropriate warning signs posted in the work area. 

 

All laser apertures should be covered by protective covers when not connected to optical 
fibers. Never leave outputs uncovered. 

 

Laser equipment should be positioned above or below eye level where possible. Apertures 
should be positioned away from personnel. 

 

Protective eyewear should be worn in the vicinity of laser equipment.

Содержание OSD159

Страница 1: ...OPERATOR MANUAL OSD159 DUPLEX 8 CHANNEL ALARM CONTACT TRANSCEIVER...

Страница 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10108502 OSD159 OPERATOR MANUAL PAGE 2 OSD159 DUPLEX 8 CHANNEL ALARM CONTACT TRANSCEIVER Document No 101085 Revision 02...

Страница 3: ...12 2 3 1 OSD159 INDICATORS 12 3 MAINTENANCE 13 3 1 INTRODUCTION 13 3 2 EXTERNAL INSPECTION 13 3 3 ROUTINE MAINTENANCE 13 4 WARRANTY 14 4 1 WARRANTY PERIOD 14 4 2 REPAIRS 14 4 2 1 WARRANTY REPAIRS 14 4...

Страница 4: ...y powered from and located in the one chassis The module versions are intended for isolated use and require an external power source The OSD159 system can be used with any standard multimode optical f...

Страница 5: ...ND OPTIONS There are various options available for the OSD159 as identified in Table 1 below OSD159 example only TABLE 1 PRODUCTS AND OPTIONS ITEM DESCRIPTION Card Version C Standalone Module Version...

Страница 6: ...ctor Optical Wavelength 850 40nm for OSD159FM 1310nm 40nm for OSD159FL Transmitter Optical Power 15dBm Receiver Sensitivity 40dBm for 1x10 9 BER Receiver Saturation 7dBm Optical Link Budget 25dB at 85...

Страница 7: ...ber Function 1 GND 14 Input 1 2 Input 2 15 Input 3 3 Input 4 16 Input 5 4 Input 6 17 Input 7 5 Input 8 18 Normally Open 1 6 Common 1 19 Normally Open 2 7 Common 2 20 Normally Open 3 8 Common 3 21 Norm...

Страница 8: ...e adequate measures OPTICAL OUTPUT OPERATION Class 1 Class 3A The multimode version of the OSD159 is a Class 1 LED product Wavelength of 850nm and 8dBm power output The singlemode versions of the OSD1...

Страница 9: ...mounted on an even surface and to be secured by means of M4 or smaller screws The OSD159 card version is designed to be inserted into a chassis and secured by means of captivated screws a Module Vers...

Страница 10: ...ernal DC power The voltage range of the OSD159 is 8 to 40VDC or 15 to 26VAC at 3VA maximum Power should be connected to the power socket located at the back of the case as indicated in Table 4 TABLE 4...

Страница 11: ...and lint free tissue to remove contamination Receive Alarm is an alarm signal that can be connected to control external sources eg LED indicator to indicate if there is a loss of received signal when...

Страница 12: ...tor illuminates accordingly on power up see Table 5 Plug in the optical connectors of the optical cable If the set up is connected correctly the OSD159 Link OK LED will change from Red to Green Plug t...

Страница 13: ...heir support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL...

Страница 14: ...e for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the r...

Страница 15: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Отзывы: