WARRANTY 

 

Thank you for purchasing equipment designed, manufactured and serviced by Optical Systems Design 
(OSD). OSD warrants that at the time of shipment, its products are free from defects in material and 
workmanship and conforms to specifications. Our Warranty conditions are outlined below: 

 
 
 

4.1

 

WARRANTY PERIOD 

 
For warranty period, please call your local OSD distributor. 
 

4.2

 

REPAIRS 

 
Optical Systems Design reserves the right to repair or replace faulty modules/units. Please obtain a 
“Return Material Authorisation” (RMA) form and number before returning goods. 
Goods must be returned in adequate packing material to Optical Systems Design, Warriewood or its 
nominated authorised representative, for all repairs. 
 
4.2.1

 

WARRANTY REPAIRS 

 
Return shipments to OSD shall be at customer's expense and freight back to the customer will be at 
OSD expense. 
 
4.2.2

 

OUT-OF-WARRANTY REPAIRS 

 
OSD reserves the right to repair or replace any faulty goods. Freight costs and insurance for both 
journeys are met by the user. All equipment repaired by OSD will have a 3-Month Warranty from the 
date of dispatch.   
 
4.2.3

 

SITE REPAIRS 

 
By agreement site repairs may be undertaken for which out of pocket, hotel and travel expenses will be 
charged. 
 
4.2.4

 

EXCLUSIONS 

 
This warranty does not apply to defects caused by unauthorized modifications, misuse, abuse or 
transport damage to the equipment. All modifications to OSD’s standard product will need written 
authorization and will be charged at normal repair rates. All modifications are to be carried out by OSD 
Technicians. Warranty is void if unauthorized removal and/or tampering with serial number and/or 
repair labels is evident.  
 

Содержание OSD159

Страница 1: ...OPERATOR MANUAL OSD159 DUPLEX 8 CHANNEL ALARM CONTACT TRANSCEIVER...

Страница 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10108502 OSD159 OPERATOR MANUAL PAGE 2 OSD159 DUPLEX 8 CHANNEL ALARM CONTACT TRANSCEIVER Document No 101085 Revision 02...

Страница 3: ...12 2 3 1 OSD159 INDICATORS 12 3 MAINTENANCE 13 3 1 INTRODUCTION 13 3 2 EXTERNAL INSPECTION 13 3 3 ROUTINE MAINTENANCE 13 4 WARRANTY 14 4 1 WARRANTY PERIOD 14 4 2 REPAIRS 14 4 2 1 WARRANTY REPAIRS 14 4...

Страница 4: ...y powered from and located in the one chassis The module versions are intended for isolated use and require an external power source The OSD159 system can be used with any standard multimode optical f...

Страница 5: ...ND OPTIONS There are various options available for the OSD159 as identified in Table 1 below OSD159 example only TABLE 1 PRODUCTS AND OPTIONS ITEM DESCRIPTION Card Version C Standalone Module Version...

Страница 6: ...ctor Optical Wavelength 850 40nm for OSD159FM 1310nm 40nm for OSD159FL Transmitter Optical Power 15dBm Receiver Sensitivity 40dBm for 1x10 9 BER Receiver Saturation 7dBm Optical Link Budget 25dB at 85...

Страница 7: ...ber Function 1 GND 14 Input 1 2 Input 2 15 Input 3 3 Input 4 16 Input 5 4 Input 6 17 Input 7 5 Input 8 18 Normally Open 1 6 Common 1 19 Normally Open 2 7 Common 2 20 Normally Open 3 8 Common 3 21 Norm...

Страница 8: ...e adequate measures OPTICAL OUTPUT OPERATION Class 1 Class 3A The multimode version of the OSD159 is a Class 1 LED product Wavelength of 850nm and 8dBm power output The singlemode versions of the OSD1...

Страница 9: ...mounted on an even surface and to be secured by means of M4 or smaller screws The OSD159 card version is designed to be inserted into a chassis and secured by means of captivated screws a Module Vers...

Страница 10: ...ernal DC power The voltage range of the OSD159 is 8 to 40VDC or 15 to 26VAC at 3VA maximum Power should be connected to the power socket located at the back of the case as indicated in Table 4 TABLE 4...

Страница 11: ...and lint free tissue to remove contamination Receive Alarm is an alarm signal that can be connected to control external sources eg LED indicator to indicate if there is a loss of received signal when...

Страница 12: ...tor illuminates accordingly on power up see Table 5 Plug in the optical connectors of the optical cable If the set up is connected correctly the OSD159 Link OK LED will change from Red to Green Plug t...

Страница 13: ...heir support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL...

Страница 14: ...e for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the r...

Страница 15: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Отзывы: