OPTICAL SYSTEMS DESIGN 

 

DOC ID: 10108502 

OSD159 OPERATOR MANUAL

 

 

PAGE 13  

 

3

 

MAINTENANCE 

 

3.1

 

INTRODUCTION 

 
 
The following section outlines the fault-finding procedure for the OSD159 modems. Please take note of 
the following: 
 

 

Personnel without appropriate training should not attempt any maintenance except that outlined 
below. 

 

 

If further maintenance is attempted you are warned that every care should be taken to ensure that 
internal measurements made while the equipment is operational are taken carefully as some 
components within the unit are expensive and may be damaged by failure of any portion of their 
support circuitry. 

 

 

Some components within the unit are Electrostatic (ES) sensitive and Electrostatic Discharge (ESD) 
precautions should be taken when performing maintenance upon the unit. 

 
 

3.2

 

EXTERNAL INSPECTION 

 
 
Visually check for the following: 
 
 

 

Check that the correct power source is connected to the power socket. 

 

 

Check that the data signals are connected to the modem correctly and that the distant OSD159 
modem has been terminated correctly to any external equipment.  

 

 

Inspect the optical connectors for any contamination and clean using isopropyl alcohol and a lint 
free tissue if any contamination is detected. 

 

 

Check that any external termination resistors are connected if the system configuration requires 
them. 

 
 

3.3

 

ROUTINE MAINTENANCE  

 
 

 

There is no routine maintenance required with the OSD159. 

 

Содержание OSD159

Страница 1: ...OPERATOR MANUAL OSD159 DUPLEX 8 CHANNEL ALARM CONTACT TRANSCEIVER...

Страница 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10108502 OSD159 OPERATOR MANUAL PAGE 2 OSD159 DUPLEX 8 CHANNEL ALARM CONTACT TRANSCEIVER Document No 101085 Revision 02...

Страница 3: ...12 2 3 1 OSD159 INDICATORS 12 3 MAINTENANCE 13 3 1 INTRODUCTION 13 3 2 EXTERNAL INSPECTION 13 3 3 ROUTINE MAINTENANCE 13 4 WARRANTY 14 4 1 WARRANTY PERIOD 14 4 2 REPAIRS 14 4 2 1 WARRANTY REPAIRS 14 4...

Страница 4: ...y powered from and located in the one chassis The module versions are intended for isolated use and require an external power source The OSD159 system can be used with any standard multimode optical f...

Страница 5: ...ND OPTIONS There are various options available for the OSD159 as identified in Table 1 below OSD159 example only TABLE 1 PRODUCTS AND OPTIONS ITEM DESCRIPTION Card Version C Standalone Module Version...

Страница 6: ...ctor Optical Wavelength 850 40nm for OSD159FM 1310nm 40nm for OSD159FL Transmitter Optical Power 15dBm Receiver Sensitivity 40dBm for 1x10 9 BER Receiver Saturation 7dBm Optical Link Budget 25dB at 85...

Страница 7: ...ber Function 1 GND 14 Input 1 2 Input 2 15 Input 3 3 Input 4 16 Input 5 4 Input 6 17 Input 7 5 Input 8 18 Normally Open 1 6 Common 1 19 Normally Open 2 7 Common 2 20 Normally Open 3 8 Common 3 21 Norm...

Страница 8: ...e adequate measures OPTICAL OUTPUT OPERATION Class 1 Class 3A The multimode version of the OSD159 is a Class 1 LED product Wavelength of 850nm and 8dBm power output The singlemode versions of the OSD1...

Страница 9: ...mounted on an even surface and to be secured by means of M4 or smaller screws The OSD159 card version is designed to be inserted into a chassis and secured by means of captivated screws a Module Vers...

Страница 10: ...ernal DC power The voltage range of the OSD159 is 8 to 40VDC or 15 to 26VAC at 3VA maximum Power should be connected to the power socket located at the back of the case as indicated in Table 4 TABLE 4...

Страница 11: ...and lint free tissue to remove contamination Receive Alarm is an alarm signal that can be connected to control external sources eg LED indicator to indicate if there is a loss of received signal when...

Страница 12: ...tor illuminates accordingly on power up see Table 5 Plug in the optical connectors of the optical cable If the set up is connected correctly the OSD159 Link OK LED will change from Red to Green Plug t...

Страница 13: ...heir support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL...

Страница 14: ...e for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the r...

Страница 15: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Отзывы: