5-11
When D-01=Time
00~23 Hr
00~59 Min
1 Min
When D-01=Battery SOC
0~100%
1%
Battery SOC is only active when terminal BCS is connected with a Shunt
50mV, 500Amp.
D-03: Aux RY1 OFF Condition
According to 9 selectable modes in D-01, use Constant D-03 to set the condition
to activate the Auxiliary Relay 1 to be OFF.
The displayed setting range of D-03 will change to less than or greater than (< or
>) depending on if D-02 or D-03 is higher or lower value. This allows setting on
either a rising or falling voltage.
Once entering the D-03, use UP and DOWN keys to increment and decrement
the values.
Aux RY1 OFF Condition
Setting Range of D-03
Setting Unit
When D-01= Solar Voltage
0~150V/0~250V
0.1V
When D-01=Output Volts
0~64V
0.1V
When D-01=Battery Volts
0~64V
0.1V
Battery Voltage is only displayed and active when terminal BVS is
connected to the battery.
When D-01=OUT Current
0~80A
1A
When D-01=BATT Current
-500~500A
1A
Battery Current is only active when terminal BCS is connected with a
Shunt 50mV, 500Amp.
The values may be positive or negative as this input reads load current as
well as charge current.
When D-01=Temp.
-20~100
1
When D-01=Battery Temp.
-20~100
1
Battery Temperature is only active when terminal BTS is connected with a
Battery Temperature Sensor (BTS-3).
When D-01=Time
00~23 Hr
00~59 Min
1 Min
When D-01=Battery SOC
0~100%
1%
Battery SOC is only active when terminal BCS is connected with a Shunt
50mV, 500Amp.
Содержание SC-160X MPPT
Страница 7: ...VII Dimension for SC 50 MPPT Unit mm Fig 1...
Страница 8: ...VIII Dimension for SC 80 MPPT Dimension for SC 80X MPPT Unit mm Fig 2...
Страница 9: ...IX Dimension for SC 160X MPPT Unit mm Fig 3...
Страница 12: ...1 3 Fig 4...
Страница 20: ...3 2 3 2 The following is the Initialization Stage Flow Chart OTPI Solar SC 80 MPPT V0 9311...
Страница 22: ...3 4 3 3 The following is the Operation Stage Flow Chart Main Menu Main Menu Operation Menu Constants...
Страница 27: ...3 9 Main Menu Programming Group F Menu Group Constants Constants Edit Data Enter...
Страница 28: ...3 10 Main Menu Programming Group O Menu Group Constants Constants Edit Data Enter...
Страница 29: ...3 11 Main Menu Data Log Menu Constants Constants Edit Data Enter...