5-7
B-07: Set Absorption Time
z
Use Constant B-07 to adjust the length of Absorption time. The factory setting is
2 hours (displayed as 02:00).
B-08: Set Float Voltage
z
Use Constant B-08 to adjust the Float voltages. The default set values are based
on the battery type and capacity selected. It is not advisable to change default
settings unless advised by the battery manufacturer or supplier.
Battery Type
Float Volts Range
Factory
Setting
FLOODED 12.9V~14.2V
13.8V
AGM 12.8V~14.2V 13.2V
GEL 12.8V~14.1V 13.5V
※
The above values are based on 12V system. The values x 2 are for 24V system;
the values x 3 are for 36V system and the values x 4 are for 48V system.
B-09: Set Equalize Voltage
z
This constant is only displayed if Flooded is selected as battery type (B-02). Use
Constant B-09 to select the Equalize voltages. The default values are based on
the battery voltage and capacity selected. It is not recommended to change
default settings unless advised so by the battery manufacturer or supplier.
Battery Type
Battery
Voltage
Equalization Volts Range
Factory
Setting
12V 14.7V~16.4V 15.6V
24V 29.4V~32.8
V 31.2V
36V
44.1V~49.2V
46.8V
FLOODED
48V 58.8V~65.6V 62.4V
B-10: Set MAX EQU. Time
z
This constant is only displayed if Flooded is selected as battery type (B-02). Use
Constant B-10 to select the time of equalization time. The factory setting is 2
hours (displayed as 02:00).
Содержание SC-160X MPPT
Страница 7: ...VII Dimension for SC 50 MPPT Unit mm Fig 1...
Страница 8: ...VIII Dimension for SC 80 MPPT Dimension for SC 80X MPPT Unit mm Fig 2...
Страница 9: ...IX Dimension for SC 160X MPPT Unit mm Fig 3...
Страница 12: ...1 3 Fig 4...
Страница 20: ...3 2 3 2 The following is the Initialization Stage Flow Chart OTPI Solar SC 80 MPPT V0 9311...
Страница 22: ...3 4 3 3 The following is the Operation Stage Flow Chart Main Menu Main Menu Operation Menu Constants...
Страница 27: ...3 9 Main Menu Programming Group F Menu Group Constants Constants Edit Data Enter...
Страница 28: ...3 10 Main Menu Programming Group O Menu Group Constants Constants Edit Data Enter...
Страница 29: ...3 11 Main Menu Data Log Menu Constants Constants Edit Data Enter...