5-5
4. Go to any display of A-xx and press DOWN key and hold it, then press ESC key
at the same time till A-04 constant occurs.
5. Enter the desired password 2 (max. 4 digits) into A-04. Make sure the password 1
in A-03 must be different from the password 2 in A-04. Finally, press ENTER key
to finish “lock” setting.
Above procedure completes locking the constants setting and no more
programming selection would appear. A-01 would only display Operation only
and would not display Constants Set.
Unlock the constants setting
1. Enter the password in A-03 to be exactly the same as the one earlier set in A-04
2. When the password in A-03 matches the one earlier set in A-04, the unlocking is
completed. A-01=Constants Set would appear again for programming.
*** Main Menu***
Programming
Group B
Battery Setup
B-01: Set Battery Voltage
During initialization of OPTI-Solar SC MPPT Series, it will detect and ask the
installer to confirm the battery voltage found is co rrect. In almost all circumstance
the OPTI-Solar SC MPPT Series will correctly detect battery voltage.
Use Constant B-01 to change the battery voltage if the battery voltage displayed
by the OPTI-Solar SC MPPT is different from the installed batteries. The selection
range of the battery voltage is 12V (Factory Setting), 24V, 36V and 48V.
B-02: Set Battery Type
Use UP or DOWN keys to allow the installer to change what type of batteries it
is connected to (Flooded, Gel, AGM) OPTI-Solar SC MPPT Series.
The default “BATTERY TYPE” is GEL
Please be sure to select the type which matches the system’s batteries. This
setting controls battery charging voltages in B-06 and B-08.
Содержание SC-160X MPPT
Страница 7: ...VII Dimension for SC 50 MPPT Unit mm Fig 1...
Страница 8: ...VIII Dimension for SC 80 MPPT Dimension for SC 80X MPPT Unit mm Fig 2...
Страница 9: ...IX Dimension for SC 160X MPPT Unit mm Fig 3...
Страница 12: ...1 3 Fig 4...
Страница 20: ...3 2 3 2 The following is the Initialization Stage Flow Chart OTPI Solar SC 80 MPPT V0 9311...
Страница 22: ...3 4 3 3 The following is the Operation Stage Flow Chart Main Menu Main Menu Operation Menu Constants...
Страница 27: ...3 9 Main Menu Programming Group F Menu Group Constants Constants Edit Data Enter...
Страница 28: ...3 10 Main Menu Programming Group O Menu Group Constants Constants Edit Data Enter...
Страница 29: ...3 11 Main Menu Data Log Menu Constants Constants Edit Data Enter...