Page 41
Confidential
– Limited Distribution
Figure 41. Adjustable Blade Ringer
Step 7
Twist the outer PVC jacket and remove it from the sensor cable. This will expose the
second jacket, which will be covered in flooding compound. The flooding compound can be
easily removed using
a cable gel solvent. The flooding compound is to seal any pin holes in
the outer jacket resulting from direct burial.
Figure 42. Cable Gel Solvent Wipe
Figure 43. Sensor cable with outer jacket removed and cleaning process
Step 8
Looking at the end of the cable, identify where the drain wire is located along the
circumference of the dielectric, also locate the slot in the shield, which is gen/- 90
degrees or a ¼ turn rotated from the drain wire. Using a sharp utility knife cut lengthwise
through the second PE jacket, avoiding cutting into the dielectric as best as possible. Cut
while staying inside the shield slot from the beginning of the cable strip point to the cable
end.