Optex ELITE PRO Скачать руководство пользователя страница 21

Preface

Installation

Troubleshooting

Specifications

21

Procedures

Color

Indicator diagram Status

Meaning

Error or warning 

generated

Red

0.7 s

2 times

Blinking twice (0.1 s 

interval) (0.7 s unlit)

Wiring error

One of the wiring errors below with OC-907C T.

Activation output (Yellow wire), stall output (Green wire), test input (Pink 

wire), BodyGuard or motor voltage input (Red wire), close switch input 

(White wire).

Displayed if the necessary wiring for auto configuration has been 

judged incomplete, or if the wiring is temporarily disconnected during 

operation.

Orange

0.7 s

2 times

Blinking twice (0.1 s 

interval) (0.7 s unlit)

Communication error

 

„

List of symptoms/causes/countermeasures

Symptom

Possible cause

Possible countermeasures

Auto configuration will 

not start

OC-907C T indicators are not 

solid

Improper power supply

Correct power problem.

Power harness connection is unsuitable

Connect the power harness correctly.

OC-907C T indicators blinking 

Orange twice (communication 

error) and no indicators solid on 

OA-607 T

Loop harness connection is unsuitable

Connect the loop harness correctly.

Pass through harness connection is 

unsuitable

Connect the pass through harness cor-

rectly.

Loop harness or pass through harness is 

disconnected

Replace as necessary.

OC-907C T indicators blinking 

Orange twice

More than two OA-607 T have been con-

nected per door

Refer to Wiring and connect OA-607 T 

suitably.

OC-907C T/OA-607 T indicators 

blinking Blue

OC-907C T dipswitch setting is incorrect

Check OC-907C T dipswitch setting.

Auto configuration 

failure

After executing auto configura

-

tion, OC-907C T indicator blinks 

Orange twice (wiring error)

Activation output (Yellow wire) is not con-

nected correctly

Refer to Wiring and connect activation 

output (Yellow wire) suitably.

Stall output (Green wire) is not connected 

correctly

Refer to Wiring and connect stall output 

(Green wire) suitably.

After executing auto configura

-

tion, OC-907C T indicator blinks 

Orange (0.5 s intervals) (setting 

error)

Automatic recognition (door angle infor-

mation, what configuration and position 

sensors are installed in) fails because door 

does not operate smoothly

Set installation positions individually with 

the setting app.

Intermittent recycle (ghosting) or intermittent stalling

After initial setup door ghosts several times 

on first activation

Happens in 15% of installations; stopping 

after first activation means system is OK.

OA-607 T sensor head not mounted flush 

on door

Head may be resting on top of door loop 

cover; reposition head flush on panel.

Improper threshold or swing area angle 

adjustment

Set threshold and swing area angles at +5 

degrees (Deep).

Motor voltage input, BodyGuard input, or 

close switch input is unsuitable

Refer to Wiring and connect motor voltage 

input, BodyGuard input, and close switch 

input suitably.

Stalling caused by traffic just outside of 

swing path or objects near guide rails

Adjust the detection area via area depth in 

the setting app.

OA-607 T dipswitch door width setting or 

setting app area setting is unsuitable

Verify proper settings.

Objects that move or emit light in the 

detection area

Remove the objects.

The detection area overlaps with that 

of another sensor

Change the OA-607 T frequency setting 

with the setting app.

Water droplets on the detection window

Install in a location protected from water 

droplets.

Sensitivity is too high

Set the sensitivity lower with the setting 

app.

Raining or snowing

Enable immunity or snow mode from the 

setting app.

No activation and/or no 

reactivation on closing 

cycle

OA-607 T sensor detects (solid or 

blinking Red indicator) (flashing: 

1st row detection, solid: 2nd/3rd 

detection) but door does not open

Improper connection of OC-907C T (Yellow 

wires) to door controller or ON/OFF/hold 

switch

Verify proper connection and output of 

activation output (Yellow wires).

On Knowing act  applications poor or 

improper connection of knowing act input 

(Purple wire) from OC-907C T to the activa-

tion device

Verify proper connection.

Auto configuration failure (configuration 

recognition failure) or incorrect setting

Check the suitable settings with the setting 

app.

OA-607 T no detection (indicator 

solid Green) (stand-by)

Sensitivity is too low

Set the sensitivity higher with the setting 

app.

OA-607 T detection window is dirty

Wipe the detection window with a damp 

cloth.

OA-607 T indicator is blinking 

Orange (configuration error within 

setting error)

Auto configuration is incomplete

Execute auto configuration (hold down 

function switch for 2 s or more).

OA-607 T indicators are blinking  

Red and Yellow alternately (in-

complete)

Power went off immediately after auto area 

learn completion (before auto-saving the 

settings)

Execute auto area learn (press function 

switch briefly).

Door failed to open due to obstacle during 

auto area learn

Remove the obstacle and then execute 

auto area learn (press function switch 

briefly).

Содержание ELITE PRO

Страница 1: ...r to the sensor system 2 Do not install the sensor where it might be directly sprayed with rainwater 3 Verify proper wiring prior to applying power to the sensor system to prevent damage to equipment 4 When setting the sensor s area pattern make sure there is no traffic around the installation site 5 Do not attempt to rebuild or repair sensor heads or control unit Contact the address in this manua...

Страница 2: ...d OA 607 T 2 ELITE PRO2 Package of OC 907C T 1 and OA 607 T 4 ELITE PRO LE Package of OC 907C T 1 and OA 607 T 1 Door type and connection pattern support are as below For single swing door Full energy doors Connection pattern OA 607 T OA 607 T OC 907C T Loop harness Model name ELITE PRO Low energy doors Connection pattern OA 607 T OC 907C T Loop harness Model name ELITE PRO LE For double swing doo...

Страница 3: ...op with concealed wiring 1 type For door loop with exposed wiring The longer 2 4 type is intended for stan dard concealed wiring applications The shorter 1 type is intended for ex posed wiring applications wiring exposed rather than embedded from the jamb cover within the jamb 6 I O harness Signal line between OC 907C T and door controller 12 pole cable Signal line for connection between door cont...

Страница 4: ...er Activation output Stall output Knowing act input Motor BG input Close switch input indicator No Name 1 Reset switch 2 Dipswitches 3 Operation indicator 4 Interface indicator From the top knowing act input activation output stall output BodyGuard motor voltage input close switch input 5 Wi Fi status indicator 6 Sensor connector 7 Door controller connector 8 Power connector No Name 1 Connector 2 ...

Страница 5: ...7C T and connecting the loop harness Connect the loop harness connector to the OC 907C T Step 4 Connecting the door front back OA 607 T Step 5 Setting the OA 607 T threshold area angle screw and swing area angle screw Step 7 OC 907C T and door controller I O wiring and OC 907C T power wiring Prepare the tools required in advance Example 1 2 3 4 5 6 7 8 1 1 Phillips head screwdriver 2 2 Phillips he...

Страница 6: ...or approach side to install the door loop on 2 Positioning the door template Position the template edge at the door edge Door template R If through holes need to be drilled door front back through hole Since the holes here are penetrated on both sides the height of the both templates should be roughly adjusted Position the door template end at the door end The door front back through hole position...

Страница 7: ...607 T sensor head 10 Position OA 607 T on the other side of the door as well Step 3 Installing the door loop only on the door loop mounting door side 1 Paste the jamb cover template on the jamb Template for jamb cover 2 Drill two 1 8 3 2 mm mounting holes in the jamb for the jamb cover in accordance with the template For concealed wiring drill an additional 3 8 10 mm cable exit hole in the middle ...

Страница 8: ...oop cover Door loop cover Wind loop harness around Loop harness Wind the harness around the door loop cover until it matches the length here NOTE NOTE As in the figure at right wrap the loop harness around the door loop cover to adjust its length 7 Fasten the door loop cover securely to the door leaf with two Black mounting screws 2 Black Fasten the door loop cover with two mounting screws 8 Conne...

Страница 9: ...f the detection angle needs to be changed see Detection area adjustment Step 6 Fitting the cover on OA 607 T 1 Put the cover on from above and fit it in Notch Pass the loop harness through the notch on the cover side Be careful not to disconnect the cable with the cover 2 Install the remaining sensors similarly Step 7 OC 907C T and door controller I O wiring and OC 907C T power wiring 1 Connect I ...

Страница 10: ...utput 3 None 4 None 5 Stall output Green Output Form A or B relay 50 V 0 3 A resistance load Set form A or B with the setting app When setting N O At power OFF Close At stand by Open At detection Close When setting N C At power OFF Close At stand by Close At detection Open 6 Stall output Green Output 7 Test input Pink Input Optocoupler voltage 5 to 30 VDC current 6 mA max 30 VDC no polarity 8 Test...

Страница 11: ...or all wiring Purple Red Yellow Green Pink White OR PUSH TO OPEN Push plate Knowing act input Relay 1 output Relay 2 delayed output Time delay module Electric lock Knowing act device e g Push plate Door controller Test output Stall input Activation input Close switch input Motor 1 2 OA 607 T OA 607 T Knowing act signal 1 Do not wire for not monitored door 2 How to connect Motor BG input Red wire R...

Страница 12: ...07 T OA 607 T Door controller Test output Stall input Activation input Close switch input Motor 1 2 Purple Knowing act signal OR Push plate PUSH TO OPEN Knowing act signal Red Yellow Green Pink White Knowing act input Relay 1 output Relay 2 delayed output Time delay module Electric lock Knowing act device e g Push plate OA 607 T OA 607 T Door controller Test output Stall input Activation input Clo...

Страница 13: ...indicator z Operation indicator Procedures Color Indicator diagram Status Meaning Before initial setup Orange Blinking 0 5 s intervals Configuration error within setting error During initial setup Orange Blinking fast 0 1 s intervals Auto configuration start Green Solid Auto configuration normally completed stand by Orange Blinking 0 5 s intervals Auto configuration abnormally completed During aut...

Страница 14: ...ial setup Orange Blinking fast 0 1 s intervals Auto configuration start Green Solid Auto configuration normally completed Orange Blinking 0 5 s intervals Auto configuration abnormally completed During auto area learn See Automatic settings and auto area learn During normal oper ation Green Solid Door fully closed Orange Solid Door closing Red Solid Door fully closed Red Blinking fast 0 1 s interva...

Страница 15: ...er dipswitch 2 Wi Fi setting to ON using Wi Fi communication and set from the setting app OC 907C T For setting OC 907C T use the dipswitch or the setting app Reset switch 2 s press Reset password after 2 s the operation indicator will turn off and return to normal operation 10 s press Reset settings to factory defaults after 10 s the operation indicator will turn off and return to normal operatio...

Страница 16: ...Meaning Green Blue Blinking among colors 0 5 s intervals Sensor setting via Wi Fi OC 907C T operation indicator Color Status Indicator diagram Meaning Green Blue Blinking among colors 0 5 s intervals Sensor setting via Wi Fi Screenshots are under development Actual specifications may vary Setting items Items Value Dipswitch setting possible OA 607 T dipswitch OC 907C T dipswitch 1st row sensitivit...

Страница 17: ...TION Adjust the areas in accordance with ANSI 156 10 5 5 0 Threshold area 1st row Swing area 2nd 3rd row Side view When both threshold area and swing area are 5 When both threshold area and swing area are 5 When both threshold area and swing area are 0 Sensor pattern H J L N B C D E F G I K M O A Threshold area 1st row Swing area 2nd 3rd row Value dimensions for each door angle feet mm Door angle ...

Страница 18: ... s intervals Auto configuration start Execute auto configuration The door will open and close two or three times automatically 1 Solid Green after normal completion Setup complete stand by Upon failure after checking the wir ing execute auto configuration again If there is no problem with the wiring manual setting from a smart device is also possible After installation is complete leave the power ...

Страница 19: ...n detection area to ensure proper operation 2 Always keep the detection window clean If dirty wipe the window with a damp cloth do not use any cleaner or solvent 3 Do not wash the sensor with water 4 Do not disassemble rebuild or repair the sensor yourself otherwise electric shock may occur 5 Contact your installer or the sales engineer if you want to change the settings 6 Do not place an object t...

Страница 20: ...utput Green wire test input Pink wire BodyGuard or motor voltage input Red wire close switch input White wire 3 Connected with sensor cable but communication is unstable Sensor cable may be disconnected or connector insertion may be loose z OC 907C T operation indicator Operation indicator Left corresponds to left side connector and right to right side connector Procedures Color Indicator diagram ...

Страница 21: ...of installations stopping after first activation means system is OK OA 607 T sensor head not mounted flush on door Head may be resting on top of door loop cover reposition head flush on panel Improper threshold or swing area angle adjustment Set threshold and swing area angles at 5 degrees Deep Motor voltage input BodyGuard input or close switch input is unsuitable Refer to Wiring and connect moto...

Страница 22: ... go to stand by OC 907C T indicators blinking Or ange twice communication error More than two OA 607 T have been con nected per door Refer to Wiring and connect OA 607 T suitably Loop harness or pass through harness is disconnected Replace as necessary OC 907C T OA 607 T indicators blinking Blue OC 907C T dipswitch setting is incorrect Check OC 907C T dipswitch setting OA 607 T indicator is blinki...

Страница 23: ... for at least 3 years after purchasing it to the individual group who made the inquiry Contact OPTEX OSS information desk E mail oss distribute optex co jp This product contains various open source software to which the following license information applies arduino esp32 GNU Lesser General Public License v2 1 AsyncElegantOTA MIT License AsyncTCP GNU Lesser General Public License v3 0 CRC MIT Licen...

Страница 24: ...rence that may cause undesired operation Le présent appareil est conforme à la partie 15 des règles de la FCC et aux normes des CNR d Innovation Sciences et Développement économique Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l appareil doit accepter tout brouillage subi mê...

Отзывы: