Preface
Installation
Troubleshooting
Specifications
20
Procedures
Color
Indicator diagram Status
When installed on approach side
When installed on swing side
Error or warning
generated
Green
Blinking (0.5 s
intervals)
Signal saturation (*1)
0.5 s
Solid/off (0.5 s only)
ANSI 500 ms OFF
When solid Green during stand-by, the indicator will go off for 0.5 s
when the door controller test signal is input, and then light up Green
again
Green
Blinking fast (0.1 s
intervals)
Sensor failure (self-monitoring) or sensitivity too low
Orange
Blinking (0.5 s
intervals)
Setting error (includes auto configuration incomplete (at initial startup))
Orange/Green
Blinking among col-
ors (0.5 s intervals)
Position error (includes shift to auto configuration when door is not fully
closed)
Red
0.7 s
2 times
Blinking twice (0.1 s
interval) (0.7 s unlit)
Wiring error (*2)
Orange
0.7 s
2 times
Blinking twice (0.1 s
interval) (0.7 s unlit)
Communication error (*3)
*1: Includes mounting position too low and wall or other object in detection range. The OA-607 T threshold value angle can be set at depth +5°
or less.
*2: One of the wiring errors below on the sensor controller side: Activation output (Yellow wire), stall output (Green wire), test input (Pink wire),
BodyGuard or motor voltage input (Red wire), close switch input (White wire).
*3: Connected with sensor cable, but communication is unstable. Sensor cable may be disconnected or connector insertion may be loose.
z
OC-907C T operation indicator
Operation indicator
(Left corresponds to left side connector
and right to right side connector)
Procedures
Color
Indicator diagram Status
Meaning
Before initial setup Orange
Blinking (0.5 s
intervals)
Configuration error within setting error
During initial setup Orange
Blinking (0.5 s
intervals)
Auto configuration abnormally completed
During background
learning
Red/Yellow
Blinking among col-
ors (0.1 s intervals)
Auto area learn Incomplete
When auto area learn is incomplete at activation, or has failed for some
reason
Error or warning
generated
Green
Blinking (0.5 s
intervals)
Signal saturation
0.5 s
Solid/off (0.5 s only) When solid Green during stand-by, the indicator will go off for 0.5 s
when the door controller test signal is input, and then light up Green
again
Green
Blinking fast (0.1 s
intervals)
Sensor failure (self-monitoring) or sensitivity too low
Orange
Blinking (0.5 s
intervals)
Setting error (includes auto configuration incomplete (at initial startup))
Orange/Green
Blinking among col-
ors (0.5 s intervals)
Position error (includes shift to auto configuration when door is not fully
closed)