Preface
Installation
Troubleshooting
Specifications
18
Automatic settings and auto area learn
Execute the following with the function switch on the OA-607 T front or with the setting app.
Auto configuration:
ELITE PRO has an advance learning system that can recognize the following system configuration and status and set the related parameters
properly and automatically for easy and quick settings.
After parameter settings, it automatically starts auto area learn to setup the area for each OA sensor heads to complete auto configuration.
● Test input (Enable or Disable)
● Test input polarity (High or Low)
● Stall output (N.O. or N.C.)
● Sensor side (Approach or Swing side)
● Hinge side (Right Hand or Left hand)
Auto area learn:
OA has a learning system that check the condition of floor surface for door opening angles.
OA-607 T function switch operation
Press front function switch
Check in advance that the door is fully closed.
WARNING
WARNING
The door opens and closes automatically, so move away from it after starting.
Procedure
Conditions
for opera-
tion
Operation
Result
Operation
Indicator
OA-607 T operation indicator
OC-907C T operation indicator
During initial
setup
Door fully
closed
Hold down the front
function switch
(more than 2 s)
Auto configuration start
Blinking fast in Orange (0.1 s intervals) = Auto configuration
start
Execute auto configuration
The door will open and close two or
three times automatically (*1).
Solid Green after normal completion
= Setup complete (stand-by)
Upon failure, after checking the wir-
ing, execute auto configuration again.
If there is no problem with the wiring,
manual setting from a smart device is
also possible.
After installation is complete, leave
the power on for at least 30 minutes
in order to achieve stable operation
during use.
Upon failure:
Blinking Orange (0.5 s intervals)
(= Setting error)
When
adjusting
the angle
or changing
the settings
after auto
configura
-
tion
None in
particular
Briefly press the
front function switch
(more than 0.3 s, no
more than 2 s) once
Start auto area learn only
Blinking fast in Yellow (0.1 s intervals) = Start auto area learn only
Execute auto area learn only
Solid Green after normal completion = Setup complete (stand-by)
Other
If the door is prevented from opening by an obstacle or the
power is cut just after auto area learn is complete: blinking
alternately Yellow and Red (0.1 s intervals) = Incomplete
*1: Twice or three times in accordance with the door controller signal input setting (combination of stall signal and test signal, etc.) during auto configuration.
NOTE
NOTE
Before executing auto configuration, the connection between the door controller and the OC-907C T sensor controller must be complete.
Auto configuration must be started with the door fully closed. Otherwise, a setting error will be generated.