background image

200

100

350

500

50

2-3 Terminal and wiring

1

 Receiver

2

 Transmitter

3

 Wiring distance

- 4 -

Caution

The speed shown above is the maximum detectable speed for each setting. 

Faster speed will not be detected. For cases where birds, newspapers, or 

suspended matters may accidentally interrupt the beam, adjust the set value to 

a slower speed (longer interruption time).

(50 msec)

(100 msec)

(200 msec)

(500 msec)

Typical 

interruption 

time setting

Time adjustment

(Receiver)

Running

Jogging

Walk fast

Slow movement

Beam interruption time adjustment

3

When using two or more units on one wire, 

the maximum length is obtained by dividing 

the maximum wire length listed right by the 

number of units. 

(a detector = a receiver or a transmitter. )

The power wire should not exceed that.

(350 msec)

Walk slow

COM N.C. N.O. SP TAMPER

POWER INPUT

10.5 to 28 VDC

ALARM OUTPUT

Form C 

(28 VDC 0.2 A max.)

SPARE

TAMPER

(N.C.)

POWER INPUT

10.5 to 28 VDC

200

100

350

500

50

200

100

350

500

50

200

100

350

500

50

200

100

350

500

50

Beam interruption time adjustment is on the receiver unit. This function allows you to adjust the sensitivity of the device to 

fit to surroundings. A slower setting means less sensitivity.

  Wire size              12 VDC                24 VDC

   AWG 22                    500                    2 500

(0.33 mm  )             (1 600)                  (8 100)

   AWG 20                     800                  4 000

(0.52 mm  )              (2 600)              (13 000)

   AWG 18                 1 200                   6 000

(0.83 mm  )             (4 000)               (19 500)

   AWG 16                  2 000                10 000

(1.31 mm  )              (6 500)              (32 500)

2

2

2

2

m (ft.)

Содержание AX-330PLUS

Страница 1: ...N 1 1 1 BEFORE YOUR OPERATION Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury Failure to follow the instructions provided with...

Страница 2: ...p of the pole Avoid aerial wiring For indoor application the wiring installation is similar to that of telephone wirings or the Internet For outdoor application use wire conduit as far as possible Som...

Страница 3: ...ng in Section 2 3 Dig out a hole on the right side of the rubber bushing marked with when it is need for the second wire Pull the wires through the wiring holes of the unit base Connect the unit base...

Страница 4: ...gth is obtained by dividing the maximum wire length listed right by the number of units a detector a receiver or a transmitter The power wire should not exceed that 350 msec Walk slow COM N C N O SP T...

Страница 5: ...comparing the measured voltage values with the parameter values in the following table To obtain an excellent alignment level the measured voltage value must be greater than 3 0V Remember to obtain t...

Страница 6: ...Tamper switch Operating temperature Environment humidity Alignment angle Installation Weight Transmitter Receiver AX 330PLUS Infrared photoelectric 100 m 330 ft 1 000 m 3 300 ft Pulsed infrared 50 to...

Страница 7: ...terrupted at a location near the receiver an alarm signal is generated Remove the alarm circuit wire from the receiver and check for short circuits on the wires When the receiver s cover is removed an...

Страница 8: ...uirement Completed Remove any objects or move the beams Go to 7 1 on the previous page OK OK NO NG NG NG START Check alignment voltage from the monitor jack Does it satisfy the minimum requirement Rem...

Отзывы: