background image

2-1 Normal installation

INSTALLATION

2

1

Range/ height/ angle

2

Pole installation

2-2 Installing method

1

2

3

4

5

- 3 -

Mounting height;

 

0.7 to 1.0 m 

(2.3 to 3.3 ft.)

Detection range;

 

100 m (330 ft.) 

max.

Horizontal

Vertical

180° (±90°)

10° (±5°)

* Mounting pole; φ43~48 mm (1 11/16’’~1 7/8’’) 

   (Standard U.S. 1 1/2’’pipe)

* The length of wiring cable out of the pole; 

   within 0.6 m (2.0 ft.)

* After finishing the pole installation, 

  align the transmitter and receiver with each other.

Loosen the cover lock screw and 

remove the front cover. 

Pull out wires through the wiring 

hole on the mounting plate and 

fix the mounting plate on the wall 

with screws.

Pole mounting

Two unit mounting

 ( back to back)

Place the front cover after the optical 

alignment and the walk test. 

( Refer to optical alignment in Section 4).

Connect wires to the terminals. 

(refer to Terminal and wiring 

in Section 2-3).

Dig out a hole on the right 

side of the rubber bushing 

marked with 

, when it is

need for the second wire.

Pull the wires through the wiring holes of the unit base. 

Connect the unit base to the mounting plate through the hook on the top of the unit base.

Push the unit base until it is fully engaged with the mounting plate.

Tighten the mounting screws on the bottom of the unit base.

Place the U-shaped bracket on the mounting 

pole, and pull out wires through the wiring 

hole on the mounting plate and fix the 

mounting plate on the U-shaped bracket 

with screws.

Fix two U-shaped brackets in layers on a pole, two 

units can be mounted back-to-back on a pole at the 

same height.

Wall mounting

Loosen the unit base mounting screw and 

slide the mounting plate downwards relative 

to the unit base to remove it.

Separating

Mounting

Wires and fixing

Connecting

Place the front cover

Tighten the cover lock screw.

about 0.6 m 

(2.0 ft.)

about 

1 m 

(3.3 ft.)

about 

0.1 m 

(3.9 inch.)

Alignment angle;

 

Knockout for the second wire

Содержание AX-330PLUS

Страница 1: ...N 1 1 1 BEFORE YOUR OPERATION Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury Failure to follow the instructions provided with...

Страница 2: ...p of the pole Avoid aerial wiring For indoor application the wiring installation is similar to that of telephone wirings or the Internet For outdoor application use wire conduit as far as possible Som...

Страница 3: ...ng in Section 2 3 Dig out a hole on the right side of the rubber bushing marked with when it is need for the second wire Pull the wires through the wiring holes of the unit base Connect the unit base...

Страница 4: ...gth is obtained by dividing the maximum wire length listed right by the number of units a detector a receiver or a transmitter The power wire should not exceed that 350 msec Walk slow COM N C N O SP T...

Страница 5: ...comparing the measured voltage values with the parameter values in the following table To obtain an excellent alignment level the measured voltage value must be greater than 3 0V Remember to obtain t...

Страница 6: ...Tamper switch Operating temperature Environment humidity Alignment angle Installation Weight Transmitter Receiver AX 330PLUS Infrared photoelectric 100 m 330 ft 1 000 m 3 300 ft Pulsed infrared 50 to...

Страница 7: ...terrupted at a location near the receiver an alarm signal is generated Remove the alarm circuit wire from the receiver and check for short circuits on the wires When the receiver s cover is removed an...

Страница 8: ...uirement Completed Remove any objects or move the beams Go to 7 1 on the previous page OK OK NO NG NG NG START Check alignment voltage from the monitor jack Does it satisfy the minimum requirement Rem...

Отзывы: