The external hopper consists of 4 main plates A, B, C, D, which you connect together one by one. Start by connecting
plates A and B, see figure 1.
Then attach square chimney frame E to plates A, B. Then put chimney frame E through and attach with the four screws
and the last square frame with a round hole, see fig. 2.
Continue by connecting side plates C and D. Continuously, or after main plates A, B, C, D have been assembled, attach legs
F to the assembly.
Once the hopper is folded, put it on the legs and slide it to the boiler. Then insert a 2 or 3m long external feeder into the
hopper chimney, see figure 7. The external hopper chimney can be rotated. Therefore, turn it so that the feeder opening
faces the burner. After inserting the feeder into the chimney, then re-adjust the hopper and feeder position so that the
feeder outlet is above the burner.
Attach the feeder to the hopper with the chain and hook so that the angle of the feeder from the ground is between 45-
55°. This ensures the expected fuel feeding.
If the boiler room space does not allow the feeder installation at this angle, it is then imperative to calibrate the feeder in
the installation set-up. After calibrating the feeder, check the pellet burning and adjust the fan speed in the Coefficients
menu in the Installation Set-up so that the flame does not create smoke.
Make sure that the feeder outlet is as far above the burner as possible so that when the burner and feeder are connected
with PVC hose, the hose will not become slack so that pellets could become stuck in the hose.
5
F
6
7
8
F
45-55°