IMP Touchless - Instruction manual
7. Going into operation
7.2 Use of the appliance
• With closed face shield it may happen during the change of
the receptacle, that the lower sensor is actuated unintentionally when
inserting the receptacle and medium penetrates. This can be prevented
if the face shield remains opened during the change/insertion
of the receptacle.
Whenever the face shield is closed, the dispenser adjusts to
the pump and then to surrounding area. Therefore all parts of the body
as well as all objects have to be removed rapidly from the immediate
vicinity after having closed the face shield.
After the change of the receptacle and/or the pump the medium has
to be pumped by repeated action (strokes).
During that hold the hand under the outlet.
The LED lights while the dispenser gauges. As soon as the light is out
the dispenser is ready for operation.
35
• With the correct opening and closing of the face shield
a different acoustic signal sounds each time.
• After the sliding on to the mounting plate the dispenser has to be
adjusted to the pump and its environment – this happens automatically
after each closing of the face shield at the end of the gauging
procedure( as described above).
• If necessary, insert the pump.
• Now insert a receptacle with the suitable medium of your choice into
the dispenser. Insert it from below via the pump and put the
receptacle with the back edge of the bottom of the receptacle onto
the base angle.
• Please make sure that the receptacle is in the right
position and can’t slip down out of the dispenser.
• Now you can use the appliance.