Link Set Settings
Figure 3-3-1 Link Set Settings
You can click
button as shown below, when there are several link set, only one can be set to the default.
Figure 3-3-2 SS7 Link Set Settings
Table 3-3-1 Definition of SS7 Link Set Settings
options
Definition
Name
The linkset’s name
Enabled
The linkset is enable or disable
Enabled_ st
The end_of_pulsing (ST) is not used to determine when incoming address is complete
Use
Connect
Reply incoming call with CON rather than ACM and ANM
Hunting
Policy
The CIC hunting policy (even_mu, odd_lru, seq_lth, seq_htl) is even CIC numbers, most recently used
Subservice
The subservice field: national (8), international l(0), auto or decimal/hex value; The auto means that the subservice is obtained
from first received SLTM.
t35
The value and action for t35. Value is in msec, action is either st or timeout; if you use overlapped dialing dial plan, you might
choose:t35=>4000,st
variant
Running under SS7 standard
OPC
The point code for this SS7 signaling point
DPC
The destination point (peer) code
Set to
Default
Set the linkset as the default linke set