Содержание OpenSprinkler 2.3

Страница 1: ... 2 Accessing the Controller 3 Homepage 3 1 Device Status 3 2 Zone Attributes 4 Menu Buttons 4 1 Rain Delay 4 2 Stop All Zones or an Individual Zone 5 Edit Options 6 Run Once Program 7 Programs 7 1 Program Data 7 2 Program Preview 7 3 Zone s Sequential Attribute 8 Logging 9 Firmware Update FAQ Support and Github Advanced Topics 1 Installing Radio Frequency RF Transmitter Specifications OpenSprinkle...

Страница 2: ... block 24VAC power adapter is NOT included by default but can be purchased as an optional add on or use your own 24VAC power adapter DC powered version comes with a black power barrel and a 7 5VDC adapter is included by default for North American users You can also use your own DC adapter with output voltage between 7 5VDC to 12VDC or use a 12VDC solar panel Though it s powered by a DC adapter it ...

Страница 3: ...Hardware Interface OpenSprinkler Firmware 2 1 9 User Manual 3 ...

Страница 4: ...one port OpenSprinkler uses software defined master pump zone so you can dedicate any zone as a master zone Installation Important Notes OpenSprinkler is NOT waterproof For outdoor use please purchase a waterproof enclosure International customers for the OpenSprinkler AC powered version please find a 24VAC transformer compatible with your country s powerline voltage standard Failure to observe th...

Страница 5: ...zone extension cable into OpenSprinkler s Zone Expander Connector the connector is polarized so you can only plug it in one way For OpenSprinkler 2 3 or OSPi plug the other end of the cable to Zone Expander s IN connector If you have multiple expanders daisy chain them by following the OUT IN links For OpenSprinkler v3 plug the other end of the cable to either of Zone Expander s connectors on the ...

Страница 6: ...s showN on the right the connector is polarized so there is only one way to plug it in Then you can plug in a wired Ethernet cable RJ45 to the other end of the module Reset WiFi Password Reset Factory Reset Reset WiFi for OpenSprinkler v3 if you need to reset or switch WiFi network without erasing program settings after controller is powered on press B3 followed by B2 B3 B2 like how you press Ctrl...

Страница 7: ... is powered on the buttons are assigned the following functions Click Press and Hold i e Long Press B1 Display device IP address Stop all zones immediately B2 Display device MAC address Reboot the controller B3 Toggle between the main controller MC and each expansion board E1 E2 E3 etc Manually start an existing program or a test program B1 B2 Display gateway router IP i e press and hold B1 then p...

Страница 8: ...lude the port number in the URL as well For example if you have changed OpenSprinkler s port number to 8080 type in http os ip 8080 Device Password the factory default password is opendoor For security reasons please change this password upon the first use TIP the OpenSprinkler mobile app has an additional feature that can automatically scan your network for available OpenSprinkler devices 3 Homep...

Страница 9: ...ked this zone will be serialized with other zones that also have the Sequential attribute turned on In other words at most one sequential zone will be running at any given time Default is on Station Type Advanced tab the default type is Standard you can also choose from several types of special virtual stations as explained below RF zone by installing a RF radio frequency transmitter see Advanced ...

Страница 10: ...w Disabled which allows disabled zones if any to show up in the zone list TIP at any time you can activate the menu by pressing the M key on your keyboard 4 1 Rain Delay To manually trigger a rain delay time click on the menu button and select Change Rain Delay to set a custom rain delay time in hours Any zone affected by rain delay will immediately stop and will not run until the rain delay time ...

Страница 11: ...ond zone will open 15 seconds prior to the closing of the first A negative station delay is sometimes useful to solve water throttling issues Default is 0 i e the next zone will run immediately after the previous Weather and Sensors Weather Adjustment Method select weather based adjustment method If Manual is selected the Watering is configured manually Otherwise the Watering is set automatically ...

Страница 12: ...ors are essentially flow activated reed switches which close and open repeatedly as water flows through the meter They do not need power and typically come with 2 wires Insert the two wires to the sensor terminals on OpenSprinkler there is no polarity Note on OpenSprinkler v3 only SN1 supports flow sensor SN2 does NOT support flow sensor Then set the flow pulse rate which you can find out in your ...

Страница 13: ...estore all options back to factory settings Reset All Station Data Restore all station names and settings to factory settings Reset Wireless Settings for OpenSprinkler v3 only reset controller to WiFi AP mode 6 Run Once Program To manually start a program go to the home page and click Run Once Program or use keyboard shortcut ALT R You can load preset water times from any of the existing programs ...

Страница 14: ...arting in days For example a program that repeats every 5 days starting in 0 day will run today and every 5th day from today A program that repeats every 3 days starting in 1 day will run tomorrow and every 3 days from then Restrictions odd even day restrictions Odd day means the program will run only if it s an odd day of the month except the 31st or Feb 29th Similarly for even days Default is no...

Страница 15: ...On Off Time are observed and all station attributes such as Use Master Station Activate Relay are also observed NOTE 2 Rain Delay and Rain Sensor are ignored because these dynamic events cannot be predicted during preview Programs that are set to Use Weather Adjustment will be scaled by the current Watering parameter When using the Manual Adjustment method the same Watering is applied to every day...

Страница 16: ...ers fans pumps To do so you need to purchase an RFtoy and use it to decode RF signal code from your remote power sockets Each code is a 16 digit long string e g 51001A0100BA00AA that encodes the on signal off signal and signal timing information The RFToy package contains a pair of 433MHz transmitter and receiver and also a pair of 315MHz ones Pick the one that matches the frequency of your wirele...

Страница 17: ...s 8 on the main controller expandable to 72 zones Max Output Current 800mA continuous per zone AC 2A continuous per zone DC Over voltage Protection Bi directional TVS on each zone power input and sensor terminal Product Size 140mmx68mmx34mm 135mmx105mmx30mm 135mmx105mmx38mm Product Weight 140g 250g 200g Expander Size 130mmx75mmx25mm Expander Weight 100g OpenSprinkler Firmware 2 1 9 User Manual 17 ...

Отзывы: