10
28582AA
RS-485 Connector Definition
The dome camera uses the RS-485 interface to communicate with a connected control device. Connect a control keyboard to the
speed dome using the terminal block. OpenEye recommends using CAT 5 cables for RS-485 communication with a maximum length
of 4000 feet (1219 meters) for 24-gauge wire. If the total cable length exceeds 4000 feet, use a repeater to maintain the signals.
Refer to the table below for pin definition and wiring.
Pin
Corresponding Pins
(22-Pin Connector)
Definition
1
7,10
T+,
R+
(D+)
2~4
Reserved
5
8,9
T-, R- (D-)
Cable Wiring and Connection
Users may need to connect cable wiring when:
•
Connecting self-provided cords to the connector housing instead of using the supplied data cable
•
Connecting alarm input and output devices.
The following table illustrates the proper way to wire cords into the connector housing.
1. Insert the terminal into the pin holes on the connector
housing, with the hook outward, as indicated in the figure.
1a. To unlock the terminal, press the hook, as indicated in the
figure, with a proper tool and pull it out gently.
2. Connect the 22-pin connector to the dome camera.