28582AA
7
Dome ID Setting
Use the switch to change your speed dome ID by turning the arrow to the desired number. For instance, if the dome ID is 123, the ID
switch should be set as below.
Centesimal Digit
Decimal Digit
Single Digit
NOTE
: No two domes should have the same ID, or communication conflict may occur
NOTE:
The number 0 should be at the top, as shown, when setting the camera ID.
Dome Control Protocol Setting
Define the protocol you are going to use based on the devices of your surveillance system. Generally, use one protocol even if the
devices are provided by different manufacturers. Use the switch to set your dome control protocol and the baud rate. Refer to the
table below and turn the arrow to choose a protocol for your speed dome.
Switch No.
Protocol
Baud Rate
00
VCL 9600
01
Pelco D
2400
02
Pelco P
4800
04
Chiper 9600
05
Philips 9600
07
OPTIX 3
9600
08
AD422 4800
09
DM P
9600
11
Pelco D
4800
12
Pelco D
9600
13
Pelco P
2400
14
Pelco P
9600
15
JVC 9600
21
Kalatel-485 9600
22
Kalatel-422 4800
EXAMPLE:
To set the protocol Pelco D, with switch no. 1 and baud rate 2400, the protocol
switch should be set as at right.
NOTE:
The number 0 should be at the top, as shown, when setting the camera ID.