5
Owner’s guide
Rev. 2.3
3.
Short circuit protection
To protect from shorted or faulty wired speaker cables the system is equipped with Actiline®
short circuit protection. If a problem is detected, the power to the speakers is automatically
turned off and the status indicator starts flashing red. To recover from short circuit mode you may
go through the following steps:
1
Turn the system off or remove mains power
2
Make sure there are no shorted wires at the Control Hub terminals or any of the speaker
terminals and that all connected speakers are Actiline® compatible.
3
Turn the system on or apply mains power
If short circuit is still detected disconnect all speakers from the Control Hub and re-connect them
one by one, following steps 1-3 above for each added speaker.