3. Now is the time to fix the radiator to the radiator bracket. Apply anticorrosive
sealant (silicone sealant) to hatched areas, to prevent corrosion. See the figure below.
Apply silicone sealant into threaded holes on the scanner radiator. Remove the cap
on the radiator bracket and orient the radiator bracket as shown in Figure 6-12.
Apply grease to the O-ring and set it to the center of the radiator bracket. Coat the
radiator fixing bolts with silicone sealant. Fasten the radiator to the radiator bracket
with the ONWA logo on the radiator facing ship`s bow.
4. Open the antenna housing cover and fix the stay as shown in Figure 6-13.
5. One end of the cable with 15-, 9- and 7-way plugs has already been connected
to CON-0906 inside the scanner housing. Mate the 15- and 9-way plugs with jacks
J812 and J811 on the transceiver module, respectively. Connect the 7-way plug to
jack J801 on the MOD Board. Secure the cable between CON-0906 and J801 with
the cable tie as shown in Figure 6-13.
Figure 6-13 Antenna unit, cover opened
Figure 6-12 Fastening the radiator to the radiator bracket
RA12