50
7.5 Anti-condensation Heater
Switch-on the mains supply in order to avoid condensation
.
7.6 Wire Cross Section
7.6.1 Wire Cross Section (Terminal Connection)
7.6.2 Wire Cross Section (Plug)
7.7 Thread Size for Cable Glands
Note:
Please use suitable certified material in hazardous areas.
Power cable
≤ 6mm
2
inflexible or 4 mm
2
flexible
Single Cable
≤ 2.5mm
2
inflexible or flexible
Operating Mode
MOE 706…MOE 725
POWER CABLE
( Inflexible or flexible)
Standard
2.5 MM
2
Option
6 MM
2
SINGLE CABLE
( Inflexible or flexible)
inverted
2.5 MM
2
Standard
Option
METRIC
PG
NPT
Terminals
(Standard)
2 x M32 X 1.5
1 x M25 X 1.5
1x PG 21
1x PG 16
1 x PG 13.5
2 x NPT 1”
1 x NPT 3/4”
Plug
(Option)
2 x M32 X 1.5
1 x M16 X 1.5
1x PG 21
1x PG 16
1 x PG 11
2 x NPT 1”
1 x NPT 1/2”
The threaded holes for the cable glands are covered with a plug when delivered.
The protection class can only be guaranteed with locally mounted cable glands.