![Onlogic Factor 202 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/onlogic/factor-202/factor-202_product-manual_1638167029.webp)
The base FR201 system is capable of operation with an input voltage ranging from 12V - 24V DC,
however different configurations will impact total system draw and may limit input voltage flexibility in
the final application.
5 - Regulatory Compliance
5.1 - CE
The computer system was evaluated for medical, IT equipment, and maritime EMC standards as a
class A device. The computer complies with the relevant equipment directives for the CE mark.
Modification of the system may void the certifications. Testing includes: EN 55032, EN 55035, IEC
60601-1, EN 62368-1, EN 60950-1, and IEC 60945. The computer is approved for co-existance of the
two provided radio transmitters when used with the specified antennas.
5.2 - FCC Statement
This device complies with part 15 of the FCC rules as a Class A device. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference and (2) this device must
accept any interference received, including interference that may cause undesired operation.
5.3 - ISED
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
CAN ICES-003(A) / NMB-003(A)
5.4 - UKCA
The computer system was evaluated for IT equipment EMC standards as a class A device. The
computer complies with the relevant IT equipment directives for the UKCA mark.
5.5 - VCCI
This is a Class A product based on the standard of the Voluntary Control Council for Interference
(VCCI). If this equipment is used in a domestic environment, radio interference may occur, in which
case the user may be required to take corrective actions.
29
Содержание Factor 202
Страница 1: ...FR202 Product Manual ...
Страница 10: ...1 4 Exterior Features and Dimensions 1 4 1 Top I O 1 4 2 Bottom I O 10 ...
Страница 11: ...1 4 3 Factor 202 Dimensions FR202 11 ...
Страница 12: ...1 5 System Block Diagrams 12 ...
Страница 15: ... Active Low Sinking Output Compatible Input Wiring Active High Sourcing Output Compatible Input Wiring 15 ...
Страница 17: ...Sourcing Output Wiring 17 ...
Страница 18: ...Sinking Output Wiring 2 2 Bottom I O Definition 18 ...
Страница 30: ...30 ...