Digital Outputs
Pin
DI 1
DI 2
1
VCC
VCC
2
DO0
DO8
3
DO1
DO9
4
DO2
DO10
5
DO3
DO11
6
DO4
DO12
7
DO5
DO13
8
DO6
DO14
9
DO7
DO15
10
GND
GND
DO terminal pinout
16 optically isolated digital outputs are provided via 2 10-pin terminal block connecters (Dinkle
0221-2010 or equivalent). Performance is optimized for 12-24V operation. Operating voltage should
not exceed 24V. Each output has a 0.5A resettable fuse.
Each group of 4 outputs (DO0-3, DO4-7, DO8-11, and DO12-15) is software-configurable to sourcing or
sinking (high- or low-side switched). For all configurations, customers must supply a VCC and GND
connection on the same connector as the outputs in use. No power is sourced for the outputs through
the system power connector.