USB 2.0
Two USB 2.0 ports are provided for peripheral usage. Together, they may deliver a maximum of 2A at
5V, depending on peripheral and device configuration.
Reset Button
The front reset button can be used to trigger a reset of the CM4. The reset button is a momentary
contact button that is tool-accessible through the chassis.
Digital Inputs
Pin
DI 1
DI 2
1
VCC
VCC
2
DI0
DI8
3
DI1
DI9
4
DI2
DI10
5
DI3
DI11
6
DI4
DI12
7
DI5
DI13
8
DI6
DI14
9
DI7
DI15
10
GND
GND
DI terminal pinout
16 optically isolated digital inputs are provided via 2 10-pin terminal block connecters (Dinkle
0221-2010 or equivalent). Performance is optimized for 12-24V operation.
Each group of 4 inputs (DI0-3, DI4-7, DI8-11, and DI12-15) is software-configurable to active-high or
active-low. The active-low configuration activates internal pull-ups to the VCC pin of the same header.
If the active-low configuration for a pin group is desired, customers must connect both VCC and GND
of that group’s connector. If the active-high configuration is used, customers must connect the GND.
Inputs are active at voltages exceeding 11.5V and inactive below 4.5V.
14
Содержание Factor 202
Страница 1: ...FR202 Product Manual ...
Страница 10: ...1 4 Exterior Features and Dimensions 1 4 1 Top I O 1 4 2 Bottom I O 10 ...
Страница 11: ...1 4 3 Factor 202 Dimensions FR202 11 ...
Страница 12: ...1 5 System Block Diagrams 12 ...
Страница 15: ... Active Low Sinking Output Compatible Input Wiring Active High Sourcing Output Compatible Input Wiring 15 ...
Страница 17: ...Sourcing Output Wiring 17 ...
Страница 18: ...Sinking Output Wiring 2 2 Bottom I O Definition 18 ...
Страница 30: ...30 ...