1.

 

GENERAL DESCRIPTION 

 
The 600 Series Pingers are high specification, microprocessor controlled acoustic transmitters 
developed  for  use  as  advanced  PIG  transmitters  and  for  other  subsea  marking  and  location 
functions. 
 
A  600  Series  Pinger  may  be  fitted  to  a  PIG  for  use  in  offshore,  fluid  filled  pipelines.  The 
acoustic  signal  generated  by  the  pinger  is  exceptionally  powerful  and  stable  and  allows  the 
approximate  PIG  location  to  be  established  from  the  surface  using  an  acoustic  receiver  and 
hydrophone  (e.g.  OEL  2001).  The  exact  location  can  then  be  determined  using  a  directional 
receiver such as the diver operated OEL PR1, or ROV mounted OEL 2001RS/2401 system. 
 
The 600 Series Pingers are highly configurable and their performance and functionality can be 
tailored  to  meet  specific  customer  requirements.  For  example,  if  two  pingers  are  required  to 
operate  in  close  proximity  to  one  another,  different  frequencies  and/or  ping  rates  can  be 
configured during manufacture to allow for differentiation between their transmissions. 
 
The 600 Series Pingers are capable of sending acoustic transmissions up to 2km, although the 
effective  range  is  dependent  upon  the  specific  configuration,  mounting  arrangement,  and 
environmental conditions. 
 

 

The standard 600 Series model (shown in the figure above) is powered by 3 Alkaline C Cells 
and produces up to 10W of acoustic power at a single operating frequency in the range of 26-
42kHz  (configured  at  time  of  manufacture).  In  addition  to  the  standard  model  a  number  of 
alternative configurations are available that offer additional functionality and/or performance: 
 
EXTENDED  HOUSING  OPTION:  Extended  housings  are  available  that  increase  the  battery 
capacity  from  3  to  4  cells.  These  configurations  have  an  increased  length  of  317mm  and  an 
increased weight in air of 1.35kg. 
 
SHORTENED HOUSING OPTION: Shortened housings are available that decrease the overall 
length to 217mm and decrease the overall weight to 0.85kg. The short version accommodates 
two C cells. 
 
LITHIUM  CELLS  OPTION:  Lithium  C  cells  may  be  fitted  in  place  of  the  standard  alkaline C 
cells  and  will  significantly  increase  the  battery  life  of  the  unit  (short  and  standard  housing 
configurations only). 
 
DUAL RATE OPTION: 600 Series Pingers with the Dual Rate option incorporate an external 
connector cable that allows them to be interfaced with an external piece of equipment for use 
as  a  long  range,  remote  alarm.  For  example,  a  600  Series  Pinger  with  the  dual  rate  option 
may be interfaced with an OEL Smart Gauge Plate and used to send an alert if the gauge plate 
is triggered. 
 
GRID™ OPTION:  Has the same functionality as the Dual Rate option above, except that the 
unit  also  transmits  the time  of  a  BWGP  event  as  a  series  of  acoustic  pulses.  This  allows  the 
location where the event occurred to be determined without having to recover the pinger first. 
 

Содержание 600 Series

Страница 1: ...d Blackburn Aberdeen AB21 0PS UK 44 0 1224 714 714 www online electronics com sales online electronics com 600 SERIES ACOUSTIC PINGER OPERATING MANUAL The 600 Series Pingers are high specification pingers used for pig tracking and other subsea marking and location functions Intended for use in pipeline diameters of 6 to 8 ...

Страница 2: ..._A01 Page 2 of 12 CONFIGURATION INFORMATION MODEL SERIAL NUMBER FREQUENCY ACOUSTIC POWER PULSE LENGTH CELL TYPE NUMBER OF CELLS PING RATE 1 RATE 1 BATTERY LIFE AT 5 C PING RATE 2 RATE 2 BATTERY LIFE AT 5 C DELAYED START TIME DD HH MM ...

Страница 3: ...C PINGER MANUAL Checked IF APPLICABLE Date IF APPLICABLE Approved Date Rev Date By Summary of change A00 01 08 17 BG CR00485 Was 600 Series Pinger Manual RevA10 CR00380 Address change CR00499 Front Cover update A01 03 10 17 BG Cover page updates COMMENTS ca 08 45 09 05 10 2017 ...

Страница 4: ...TIONS 6 3 RULES FOR SAFE OPERATION 7 4 OPERATION 8 4 1 FUNCTION TEST 8 4 2 INSTALLATION 8 4 3 DEPLOYMENT 9 4 4 BATTERY REPLACEMENT 9 4 5 DUAL RATE 10 4 6 GRID 10 4 7 DELAYED START 10 5 MAINTENANCE 11 5 1 O RING REPLACEMENT 11 5 2 ROUTINE MAINTENANCE AND STORAGE 11 6 WARRANTY 11 7 DISPOSAL OF UNIT 12 ...

Страница 5: ...red by 3 Alkaline C Cells and produces up to 10W of acoustic power at a single operating frequency in the range of 26 42kHz configured at time of manufacture In addition to the standard model a number of alternative configurations are available that offer additional functionality and or performance EXTENDED HOUSING OPTION Extended housings are available that increase the battery capacity from 3 to...

Страница 6: ...attern Omni directional 3dB Operating Frequency Pre Configured within 26 42 kHz Pulse Length 5ms 5 as standard Configurable between 1 and 30 ms Ping Rate From 1 ping per second to 1 ping every 30 seconds Operating Temperature Range 2 C to 54 C External Pressure Rating 3000m 300bar Weight in Air 1 1kg MATERIALS Housing Material 316 STAINLESS STEEL Endcap Material ALLOY BRONZE Transducer Material PE...

Страница 7: ...place all batteries at the same time NEVER install used batteries NEVER install a mix of new and used batteries USE ONLY new batteries from the same package or manufacturing batch DO NOT mix different brands or types of batteries ALWAYS observe correct battery polarity New batteries should be installed before each deployment WARNING Do not expose to aggressive solvents or chemicals which could be ...

Страница 8: ...f the pinger Refer to Page 2 of this manual for the PING RATES of the unit supplied 5 If a pinger with the dual rate option is being tested then either PING RATE 1 or PING RATE 2 will be transmitted depending on whether the DUAL RATE contact is open or grounded Refer to Section 4 5 DUAL RATE for further information If the wrong ping rate is being transmitted this would suggest that the external eq...

Страница 9: ... salt water fresh water or MEG If using the mechanical link to bridge the contacts the heat shrink will need to be removed beforehand 7 Perform a FUNCTION TEST as described in Section 4 Providing the function test has been completed successfully deployment can proceed 4 4 BATTERY REPLACEMENT 1 Familiarise yourself with the NOTES given at the start of Section 3 RULES FOR SAFE OPERATION 2 Remove the...

Страница 10: ...l moulded into the transducer The functionality of the GRID units is similar those with DUAL RATE except that the unit also logs the time of a gauge plate event and then transmits it at set intervals as a series of acoustic pulses These pulses can then be decoded in order to determine the location at which the gauge plate occurred without the need to recover the pig first Interfacing the unit with...

Страница 11: ...th a suitable grease e g DOW CORNING MOLYKOTE 111 COMPOUND 6 Referring to Section 4 4 BATTERY REPLACEMENT re insert the batteries and then refit the BATTERY ENDCAP to the battery end of the housing 5 2 ROUTINE MAINTENANCE AND STORAGE All Online Electronics Ltd products are designed to require minimum maintenance The housing should be cleaned using fresh water and cleaning agents as necessary Do no...

Страница 12: ... but must be separately collected for the proper treatment and recovery The crossed out bin symbol placed on the product reminds you of the need to dispose it correctly at the end of its life When buying a new product you will have the opportunity to return free of charge another end of life product of equivalent type that has fulfilled the same functions as the supplied equipment These items may ...

Отзывы: