22
A d j u s t m e n t M a n u a l
Item High
Voltage
Confirmation
Adj.Process 2AL
3G(UE-DLX)
M o d e l
ALL
Measuring
Equipment
* High Voltage meter
Preparation
before Adj.
* Warm up the set sufficiently before adjustment.
Adjustment
Procedure
DON’T SWITCH ON THE TV SET. /
SWITCH OFF THE SET
1) Connect the earth clip of the high
voltmeter to the chassis.
2) Connect the probe of High Voltage meter
to the anode of the CRT.
3) Switch ON the Set & receive the
monoscope signal
and check for the High Voltage meter
reading is as per the table given below.
MODEL
LOWER LIMIT
STANDARD
UPPER LIMIT
14" 22KV 23KV 24KV
20"
25 KV
26 KV
28 KV
4)
Disconnect the probe side first & next the
earth side.
NOTE : Electrostatic type of the high voltmeter
should be used as the measuring
apparatus.
However when a high voltmeter with
1000M
Ω
input resistance is used, the
value should be read 0.3kV lower than
the measured value.