A d j u s t m e n t M a n u a l
I
2
C
Item
High light Adjustment Adj.Process 2AL
3G(UE-DLX)
M o d e l
ALL
Measuring
Equipment
* Colour Analyzer
Preparation
before Adj.
* Warm up the receiver for more than 30 minutes.
* The low light adjustment should be done in advance.
Adjustment
1) Receive the monoscope pattern signal .
Procedure 2)
Select
R-DRIVE
&/OR
B
DRIVE
in the
Service Menu.
3)
Adjust
R-
DRIVE
& B-
DRIVE
so that the
white balance is at the directed value
(Adjustment point “A”).
4) Check if the tracking of white balance
from Low light till High light is good.
Model
Adjustment point A
Colour
temperature
X Y
ALL 9300°
K
0.290
0.291
5) Receive the pedestal pattern signal .
6) Check if the white balance of low light is
good. If the white balance of the low light
is not good, adjust the low light again.
7) Receive the monoscope pattern signal.
Repeat step (4) onwards till perfect white
balance is achieved in low light and high
light paterns.
12