7-3
FIGURE 7-3. CLEANING BREATHER
C1014
CRANKCASE
BREATHER
TUBE
CLEAN
CRANKCASE
BREATHER
PIPE EVERY
500 HOURS
CRANKCASE BREATHER
After every 200 hours of operation, remove hose clamp,
breather hose, breather cap clamp and insulator halves
to release breather cap and valve assembly, Figure 7-4.
Wash cap, valve assembly and baffle in suitable solvent.
Dry and reinstall.
FIGURE 7-4. CRANKCASE BREATHER
LS1206C
BREATHER
HOSE
SCREEN
SCREEN
RETAINER
CLAMP
OIL
BAFFLE
ASSEMBLY
BREATHER
TUBE
FILTER
O-RING
CAP AND VALVE
HOSE CLAMP