Table 31. Minimum Vertical Blanking Configuration
R0x3180[0x00F0]
OB Rows
minimum_vertical_blanking
0x8 (Default)
8 OB Rows
8 OB + 4 = 12
0x4
4 OB Rows
4 OB + 4 = 8
0x2
2 OB Rows
2 OB + 4 = 6
The locations of the OB rows, embedded rows, and blank
rows within the frame readout are identified in Figure 30: