About Communication Commands
ZFX-C Serial Communication Command Reference
49
Size inspection parameters
Area
Data No.
Parameter
Output Range
52
Measure axis angle
0: OFF, 1: ON
53
Fill profile
0: OFF, 1: ON
54
Calibration
0: OFF, 1: ON
55
Coordinates mode
0: Normal 1: Pos. correction
71
Area upper limit value
0.000 to 9999999.999
72
Area lower limit value
0.000 to 9999999.999
73
Gravity position X upper limit value
-9999.999 to 9999.999
74
Gravity position X lower limit value
-9999.999 to 9999.999
75
Gravity position Y upper limit value
-9999.999 to 9999.999
76
Gravity position Y lower limit value
-9999.999 to 9999.999
77
Axis angle upper limit value
-90.00 to 90.00
78
Axis angle lower limit value
-90.00 to 90.00