manualshive.com logo in svg
background image

Classification

Functions

Span adjuster
(Amplifier)

The output is adjusted to approximately 8 V FS before shipping.

The span adjustment changes the ratio of the output current (displacement) to the distance. By using the
span adjustment, the actual current-distance relationship can be changed to either a higher output current at
the same distance or to a lower output current. When there are changes in material or color in the target
object, and a 1:1 ratio is not obtained, span adjustment is used to modify the current output level.

With the span adjuster, it is possible to adjust the full scale of the voltage (

±

30%) that is output when the

object is within the measurement range.

For the step-by step Operating/Adjusting procedure refer to

-- Span Adjustment (in a subsequent section).

+30%
-30%

+30%
-30%

Sensing
distance
(mm)

Sensing
distance
(mm)

Li

near

output

(V

)

Li

near

output

(V

)

Z4M-W40

Z4M-W100

Enable output
(Amplifier)

The enable output is ON when the Sensor is performing a displacement measuring operation.

The enable output is OFF when there is no object in front of the Sensor or if the light reflected from the object
is insufficient or too intense.

An open collector output of 50 mA at 40 VDC maximum can be obtained.

In the case of measuring an metal or glossy object, the enable output may be ON even if the object is outside
the measurement range.

Linear output
(Amplifier)

An analog voltage signal according to the measuring distance will be output from the output line (black shield
wire).

Voltage output: -4 to 4 V/30 to 50 mm (Z4M-W40), -4 to 4 V/60 to 140 mm (Z4M-W100)

Output impedance: 100

(typical)

The linear output will be locked between 6 and 8 V when the enable output is OFF.

Laser OFF input
(Amplifier)

The laser OFF input controls laser emission.

Laser emission is turned on when there is no laser OFF input (with a current leakage of 0.1 mA max.) and it is
turned off when the laser OFF input is short-circuited to the 0-V terminal (with a residual voltage of 2 V max.).

When laser emission is turned Off, the linear output, indicators, and the enable output of the Sensor are on
hold.

There will be a drift of 0.1% FS/s when the analog output of the Sensor is on hold.

The response time required to turn laser emission ON or OFF is 3 ms max.

Laser emission
delaying function
(Sensor and Amplifier)

When the Sensor is turned ON, the range indicators (green) will blink for 3 to 10 s, alerting the user to laser
emission; during this time the linear output is locked between 6 and 8 V. After this time, the laser beam will be
turned ON.

OPERATIONAL EXAMPLES: Z4M SENSOR AND K3TS INTELLIGENT DIGITAL PANEL METER

Measurement distance (set to 40 mm)

Timing input

Deflection value = maximum value - minimum value

K3TS

Note:

Use a pushbutton switch to turn ON the timing
input while measuring eccentricity.

Measuring Eccentricity

Using the scaling function, it is possible to convert the
Sensor’s output (

±

4 V) into the actual measured dimension

of the object for display.

By selecting the appropriate measurement mode that corre-
sponds to the application, necessary data can be easily ob-
tained. In the following application, the peak-to-peak hold
mode is used to measure the eccentricity of an object by
measuring the difference between the maximum and
minimum values while the timing input is ON.

Z4M

Z4M

Содержание Z4M-W10

Страница 1: ... minimizes sensing errors caused by color or surface variations Compact sensor head incorporates easy to use range indicators Amplifier can be DIN rail mounted Connects to the Z49 SF2 Laser Safety Kit to conform to FDA standards Ordering Information SENSORS Sensing distance Resolution response speed selected Part number 40 10 mm 1 57 40in 1 5 µm 60 ms 10 µm 2 ms 40 µm 0 15 ms Z4M W40 100 40 mm 3 9...

Страница 2: ...onversion value of the analog output Condition white alumina ceramic at the measurement point Linearity see Note 2 1 FS see Note 1 1 5 FS see Note 1 Response time see Note 3 0 15 ms 2 ms 60 ms switch selectable 0 7 ms 20 ms 500 ms switch selectable Sensitivity selector WHITE BLACK AUTO switch selectable Temperature characteristics at measurement point Sensor 0 03 FS C Amplifier 0 03 FS C Sensor 0 ...

Страница 3: ...sponse time Response time CHARACTERISTICS Power supply voltage 12 to 24 VDC 10 ripple p p 10 max Current consumption 120 mA max Dielectric strength Sensor 1 000 VAC 50 60 Hz for 1 min Amplifier 300 VAC 50 60 Hz for 1 min Vibration resistance Destruction 10 to 55 Hz 1 5 mm double amplitude for 32 minutes each in X Y and Z directions Shock resistance Destruction 300 m s2 30G for 3 times each in X Y ...

Страница 4: ...or FS White ceramic Black paper Rolled steel plate Inclination angle Inclination angle Inclination angle Error FS See note Note Rolled steel cannot be meas ured due to excessive light reflection SPOT DIAMETER TYPICAL EXAMPLE L l1 l2 Cross section of the beam Z4M W40 Distance L 30 mm 1 18 in 40 mm 1 57 in 50 mm 1 97 in 1 1 2 mm 0 047 in 0 6 mm 0 024 in 0 2 mm 0 008 in 2 0 6 mm 0 024 in 0 3 mm 0 012...

Страница 5: ...surement point distance in mm Error FS White ceramic Black paper Rolled steel plate Inclination angle 10 Z4M W100 Inclined Object Inclined Object Inclined Object Inclination angle 0 Error FS Measurement point distance in mm White ceramic Black paper Rolled steel plate White ceramic Black paper Rolled steel plate Inclination angle 10 Error FS Measurement point distance in mm White ceramic Black pap...

Страница 6: ...An English warning sticker is provided with the model At tach the sticker here Emitter laser beam emitter Receiver Connector AMPLIFIER Stability indicator Offset adjustor Span adjustor Sensitivity selector Response speed selector Connector terminals NEAR indicator FAR indicator Z4M Z4M ...

Страница 7: ...is stable If the indicator is not lit in green while the sensitivity selector is set to WHITE set it to BLACK or AUTO for a more stable measuring operation Normal output can be obtained even if the indicator is not lit in green The indicator will be lit in red when there is no object in front of the Sensor or if the light reflected from the object is either insufficient or too intense If the indic...

Страница 8: ...V 60 to 140 mm Z4M W100 Output impedance 100 Ω typical The linear output will be locked between 6 and 8 V when the enable output is OFF Laser OFF input Amplifier The laser OFF input controls laser emission Laser emission is turned on when there is no laser OFF input with a current leakage of 0 1 mA max and it is turned off when the laser OFF input is short circuited to the 0 V terminal with a resi...

Страница 9: ...e linear output is 0V Y2 A distance of 40 mm between the object and the Sensor is regarded as the standard distance 0 mm X1 The linear output is 0 4 V 400 mV Y1 When the sensing distance is 41 mm the difference between the sensing distance and the standard distance is 1 mm Set the decimal points of Y2 and Y1 Prohibits comparison set point change in the RUN mode After all settings have been complet...

Страница 10: ...ws 1 Locate the object at the standard distance and adjust the offset ad justment 2 Move the object for a specified distance and adjust the span adjuster so that the voltage will change properly according to the displace ment Follow these steps to convert 4 V to 5V 1 Connect an Intelligent Panel Meter to the Sensor and move the object so that the output will be 4 V 2 Use the span adjuster to adjus...

Страница 11: ...length 2 m Enlarged view of mounting hole 25 Two M4 Taps 25 30 1 18 80 98 3 86 89 15 26 4 8 42 7 5 2 12 5 3 3 6 21 35 2 55 2 17 6 0 7 4 4 5 5 30 Mounting Holes 1 39 3 15 3 50 ACCESSORIES SOLD SEPARATELY Oil resistive vinyl insulated shielded cable external diameter 6 6 11 9 dia 14 dia 14 7 dia 9 5 dia 43 43 3 m 9 84ft or 8 m 26 25 ft Extension Cable Z49 C1 Laser Safety Kit Z49 SF2 Z4M Z4M ...

Страница 12: ...ut of the Sensor will be on hold Linear output 4 to 4 V will be output according to the displacement value Wire the Sensor correctly or the sensor may be damaged The linear output line must not be in contact with any other line Linear GND Used as a ground 0V terminal for the linear output of the Sensor Connect this line to the input device Note 1 The 0 V blue and linear GND shielded line are inter...

Страница 13: ...er than 130 Vrms between terminals Laser Radiation Emission Indicator The system incorporates an emission indicator which gives a visible or audible signal from 2 to 20 seconds before and during radiation emission Visible indicators should be visible to users wearing laser protection glasses Safety Interlocks Safety interlocks are fitted to each part of the protective housing to prevent the emissi...

Страница 14: ...placement Sensor cannot accurately detect objects that are mirror like transparent inclined or have an extremely small reflection ratio smaller than the Sensor s sensing spot diameter DANGER Do not wire the power supply cable for the Z4M Sensor in the same conduit with high voltage lines or power lines The result would be interference damage or malfunction WIRING A Z49 C1 Extension Cable can be co...

Отзывы: