Note: 1. The FS (Full Scale) value (listed in the preceding table) is calculated as follows:

Example: 1% FS on the Z4M-W40
Distance full scale conversion: 20 mm x 0.01 = 0.2 mm
Voltage full scale conversion: 8 V x 0.01 = 80 mV

Part Number

Z4M-W40

Z4M-W100

Distance full scale

20 mm

80 mm

Voltage full scale (The value changes
according to the span to be adjusted.)

8 V

±

30%

8 V

±

30%

2. The linearity of the Sensor is checked with a

white alumina ceramic object. The peak-to-peak
value deviated from the displacement linear output
voltage is within the specified range as shown in
the graph. The deviation value may vary with the
object. (Refer to the preceding table.)

1% max.

30

50

Output

vol

tage

(V

)

4

--4

Distance (mm)

3. The response speed of the Sensor is the

time required for the analog displacement
output to increase from 10% to 90% of the
full value (at the rise time) or decrease from
90% to 10% of the full value (at the fall time).
To decrease the error ratio to within 1% at
the rise time, the time required will be two or
three times as long as the specified value.
(Refer to the preceding table.)

Displacement

Displacement
output

90%

10%

90%

10%

Response time

Response time

CHARACTERISTICS

Power supply voltage

12 to 24 VDC

±

10%, ripple (p-p): 10% max.

Current consumption

120 mA max.

Dielectric strength

Sensor: 1,000 VAC, 50/60 Hz for 1 min.

Amplifier: 300 VAC, 50/60 Hz for 1 min.

Vibration resistance

Destruction: 10 to 55 Hz (1.5-mm double amplitude) for 32 minutes each in X, Y, and Z
directions

Shock resistance

Destruction: 300 m/s

2

, 30G for 3 times each in

±

X, Y, and Z directions

Ambient temperature

Operating: 0

°

to 50

°

C (32

°

to 122

°

F) with no icing

Ambient humidity

Operating: 35% to 85% (with no condensation)

Ambient illumination

Operating: 3,000 lux max. (incandescent lamp)

Weight

Sensor:

Approx. 180 g (6.35 oz.) with 2-m cable

Amplifier: Approx. 200 g (7.05 oz.) without cable

Material

Sensor:

Aluminum diecast

Amplifier: ABS

Enclosure rating

IP40

Accessories supplied

Flat-blade screwdriver for Sensor adjustment, FDA Caution Label

Engineering Data

LINEAR OUTPUT vs

.

SENSING DISTANCE

Z4M-W40

Z4M-W100

Li

near

output

(V

)

Measurement range
(20 mm)

Sensing distance

Li

near

output

(V

)

Measurement range
(80 mm)

Sensing distance

Note: The linear output of the Sensor is locked between 6 and 8 V when the object is outside the measurement range or when the en-

able output is OFF. It is also locked between 6 and 8 V for 3 to 10 s after the Sensor is turned on, at which time there is no laser
emission.

Z4M

Z4M

Содержание Z4M-W10

Страница 1: ... minimizes sensing errors caused by color or surface variations Compact sensor head incorporates easy to use range indicators Amplifier can be DIN rail mounted Connects to the Z49 SF2 Laser Safety Kit to conform to FDA standards Ordering Information SENSORS Sensing distance Resolution response speed selected Part number 40 10 mm 1 57 40in 1 5 µm 60 ms 10 µm 2 ms 40 µm 0 15 ms Z4M W40 100 40 mm 3 9...

Страница 2: ...onversion value of the analog output Condition white alumina ceramic at the measurement point Linearity see Note 2 1 FS see Note 1 1 5 FS see Note 1 Response time see Note 3 0 15 ms 2 ms 60 ms switch selectable 0 7 ms 20 ms 500 ms switch selectable Sensitivity selector WHITE BLACK AUTO switch selectable Temperature characteristics at measurement point Sensor 0 03 FS C Amplifier 0 03 FS C Sensor 0 ...

Страница 3: ...sponse time Response time CHARACTERISTICS Power supply voltage 12 to 24 VDC 10 ripple p p 10 max Current consumption 120 mA max Dielectric strength Sensor 1 000 VAC 50 60 Hz for 1 min Amplifier 300 VAC 50 60 Hz for 1 min Vibration resistance Destruction 10 to 55 Hz 1 5 mm double amplitude for 32 minutes each in X Y and Z directions Shock resistance Destruction 300 m s2 30G for 3 times each in X Y ...

Страница 4: ...or FS White ceramic Black paper Rolled steel plate Inclination angle Inclination angle Inclination angle Error FS See note Note Rolled steel cannot be meas ured due to excessive light reflection SPOT DIAMETER TYPICAL EXAMPLE L l1 l2 Cross section of the beam Z4M W40 Distance L 30 mm 1 18 in 40 mm 1 57 in 50 mm 1 97 in 1 1 2 mm 0 047 in 0 6 mm 0 024 in 0 2 mm 0 008 in 2 0 6 mm 0 024 in 0 3 mm 0 012...

Страница 5: ...surement point distance in mm Error FS White ceramic Black paper Rolled steel plate Inclination angle 10 Z4M W100 Inclined Object Inclined Object Inclined Object Inclination angle 0 Error FS Measurement point distance in mm White ceramic Black paper Rolled steel plate White ceramic Black paper Rolled steel plate Inclination angle 10 Error FS Measurement point distance in mm White ceramic Black pap...

Страница 6: ...An English warning sticker is provided with the model At tach the sticker here Emitter laser beam emitter Receiver Connector AMPLIFIER Stability indicator Offset adjustor Span adjustor Sensitivity selector Response speed selector Connector terminals NEAR indicator FAR indicator Z4M Z4M ...

Страница 7: ...is stable If the indicator is not lit in green while the sensitivity selector is set to WHITE set it to BLACK or AUTO for a more stable measuring operation Normal output can be obtained even if the indicator is not lit in green The indicator will be lit in red when there is no object in front of the Sensor or if the light reflected from the object is either insufficient or too intense If the indic...

Страница 8: ...V 60 to 140 mm Z4M W100 Output impedance 100 Ω typical The linear output will be locked between 6 and 8 V when the enable output is OFF Laser OFF input Amplifier The laser OFF input controls laser emission Laser emission is turned on when there is no laser OFF input with a current leakage of 0 1 mA max and it is turned off when the laser OFF input is short circuited to the 0 V terminal with a resi...

Страница 9: ...e linear output is 0V Y2 A distance of 40 mm between the object and the Sensor is regarded as the standard distance 0 mm X1 The linear output is 0 4 V 400 mV Y1 When the sensing distance is 41 mm the difference between the sensing distance and the standard distance is 1 mm Set the decimal points of Y2 and Y1 Prohibits comparison set point change in the RUN mode After all settings have been complet...

Страница 10: ...ws 1 Locate the object at the standard distance and adjust the offset ad justment 2 Move the object for a specified distance and adjust the span adjuster so that the voltage will change properly according to the displace ment Follow these steps to convert 4 V to 5V 1 Connect an Intelligent Panel Meter to the Sensor and move the object so that the output will be 4 V 2 Use the span adjuster to adjus...

Страница 11: ...length 2 m Enlarged view of mounting hole 25 Two M4 Taps 25 30 1 18 80 98 3 86 89 15 26 4 8 42 7 5 2 12 5 3 3 6 21 35 2 55 2 17 6 0 7 4 4 5 5 30 Mounting Holes 1 39 3 15 3 50 ACCESSORIES SOLD SEPARATELY Oil resistive vinyl insulated shielded cable external diameter 6 6 11 9 dia 14 dia 14 7 dia 9 5 dia 43 43 3 m 9 84ft or 8 m 26 25 ft Extension Cable Z49 C1 Laser Safety Kit Z49 SF2 Z4M Z4M ...

Страница 12: ...ut of the Sensor will be on hold Linear output 4 to 4 V will be output according to the displacement value Wire the Sensor correctly or the sensor may be damaged The linear output line must not be in contact with any other line Linear GND Used as a ground 0V terminal for the linear output of the Sensor Connect this line to the input device Note 1 The 0 V blue and linear GND shielded line are inter...

Страница 13: ...er than 130 Vrms between terminals Laser Radiation Emission Indicator The system incorporates an emission indicator which gives a visible or audible signal from 2 to 20 seconds before and during radiation emission Visible indicators should be visible to users wearing laser protection glasses Safety Interlocks Safety interlocks are fitted to each part of the protective housing to prevent the emissi...

Страница 14: ...placement Sensor cannot accurately detect objects that are mirror like transparent inclined or have an extremely small reflection ratio smaller than the Sensor s sensing spot diameter DANGER Do not wire the power supply cable for the Z4M Sensor in the same conduit with high voltage lines or power lines The result would be interference damage or malfunction WIRING A Z49 C1 Extension Cable can be co...

Отзывы: