97
NC Unit Error Logs
Section 10-1
Origin search
(continued)
Origin mode selec-
tion error
1604
The axis parameters’ origin search
operating mode selection setting is not
0, 1, 2, or 3.
Transfer the data
again after
checking and
correcting it.
When this
error occurs
during data
transfer, all
data (includ-
ing the data
with the error)
specified for
transfer will
be lost.
All operating
axes will be
decelerated
to a stop.
Origin search opera-
tion error
1605
The axis parameters’ origin search
operation setting is not 0, 1, or 2.
Origin search direc-
tion error
1606
The axis parameters’ origin search
direction is not 0 or 1.
Origin detection
method error
1607
Even though the axis parameters’ origin
search operation is not set to single-
direction mode, the origin detection
method setting is not 0, 1, or 2.
Backlash
compensa-
tion
Backlash compen-
sation error
1700
The axis parameters’ backlash compen-
sation setting is outside the settable
range (0 to 9,999pulses).
Backlash compen-
sation speed error
1710
The axis parameters’ backlash compen-
sation speed setting exceeds the maxi-
mum speed setting.
Software lim-
its
CW software limit
error
1800
The axis parameters’ CW software limit
setting is outside the settable range
(–1,073,741,823 to 1,073,741,823).
CCW software limit
error
1801
The axis parameters’ CCW software
limit setting is outside the settable range
(–1,073,741,823 to 1,073,741,823).
Zones
Zone 0 CW error
1900
Zone 0’s CW data is outside the setta-
ble range (–1,073,741,823 to
1,073,741,823).
Zone 0 CCW error
1901
Zone 0’s CCW data is outside the setta-
ble range (–1,073,741,823 to
1,073,741,823).
Zone 1 CW error
1910
Zone 1’s CW data is outside the setta-
ble range (–1,073,741,823 to
1,073,741,823).
Zone 1 CCW error
1911
Zone 1’s CCW data is outside the setta-
ble range (–1,073,741,823 to
1,073,741,823).
Zone 2 CW error
1920
Zone 2’s CW data is outside the setta-
ble range (–1,073,741,823 to
1,073,741,823).
Zone 2 CCW error
1921
Zone 2’s CCW data is outside the setta-
ble range (–1,073,741,823 to
1,073,741,823).
Position data
Target position error
2000
to
2099
The position data is outside the settable
range (–1,073,741,823 to
1,073,741,823).
(The last two digits of the code indicate
the position data number where the
error occurred.)
Item
Name
Code
Cause
Clearing
method
Operation
after error