manualshive.com logo in svg
background image

 

 

 

 

 
 

 

Machine Automation Controller NJ-series

 
 

EtherCAT(R) C

onnection Guide

 

WAGO Kontakttechnik

 

GmbH & Co. KG 

WAGO-I/O-SYSTEM Fieldbus Coupler

 

(750 Series)

 

 

    
     

  
  
  

 

 

 

 

 

 
 

 
 

 

 
 

 

 
 

 
 

 

 
 

 

 

 

P

5

9

4

-

E1-01

 

 

Содержание WAGO-I/O-SYSTEM

Страница 1: ...Machine Automation Controller NJ series EtherCAT R Connection Guide WAGO Kontakttechnik GmbH Co KG WAGO I O SYSTEM Fieldbus Coupler 750 Series P594 E1 01...

Страница 2: ...in the USA and other countries EtherCAT R is registered trademark and patented technology licensed by Beckhoff Automation GmbH Germany Sysmac is a trademark or registered trademark of OMRON Corporati...

Страница 3: ...ation 5 6 EtherCAT Settings 7 6 1 EtherCAT Communications Parameter Settings 7 6 2 Allocation for PDO Communications 7 7 EtherCAT Connection Procedure 9 7 1 Work Flow 9 7 2 Setting Up the WAGO I O SYS...

Страница 4: ...the system Cat No Model Manual name W500 NJ501 NJ301 NJ series CPU Unit Hardware User s Manual W501 NJ501 NJ301 NJ series CPU Unit Software User s Manual W505 NJ501 NJ301 NJ series CPU Unit Built in E...

Страница 5: ...Communications Communications using Service Data Objects This method is used to read and write the specified slave unit data from the master unit when required The NJ series Machine Automation Contro...

Страница 6: ...ct to change without notice for improvement The following notations are used in this document Indicates a potentially hazardous situation which if not avoided will result in minor or moderate injury o...

Страница 7: ...recautions for Correct Use As applicable devices above the devices with the models and versions listed in Section 5 2 are actually used in this document to describe the procedure for connecting device...

Страница 8: ...ection Switch 750 354 000 001 Rev 0x00010002 WAGO Power supply module 750 602 WAGO 2 channel digital output module 750 501 WAGO 4 channel digital input module 750 407 WAGO End module 750 600 WAGO ESI...

Страница 9: ...update function If a version not specified in this section is used the procedures described in Section 7 and subsequent sections may not be applicable In that case use the equivalent procedures descri...

Страница 10: ...2 Allocation for PDO Communications The EtherCAT PDO communications data of the Destination Device are allocated to the Controller s device variables The device variables and the data types are shown...

Страница 11: ...ata_Hold_Ac_F100_03 BOOL Output Process Data Hold Acknowledge E001_Input_Output_Process_Data_Clear_A_F100_04 BOOL Output Process Data Clear Acknowledge E001_Input_New_Message_Available_10F3_04 BOOL Di...

Страница 12: ...e WAGO I O SYSTEM Fieldbus Coupler 7 3 Setting Up the Controller Set up the Controller 7 3 1 Starting the Sysmac Studio and Installing the ESI File Install the ESI file for the WAGO I O SYSTEM Fieldbu...

Страница 13: ...input module are connected as an I O Unit as shown on the right If the power supply is turned ON settings may not be applicable as described in the following procedures 2 Check the position of the ha...

Страница 14: ...therCAT port PORT2 of the Controller and connect the USB cable to the peripheral USB port As shown in 5 2 Device Configuration connect the Personal computer WAGO I O SYSTEM Fieldbus Coupler and Contro...

Страница 15: ...click the Yes or OK Button to proceed with the processing 6 A confirmation dialog box is displayed Check the contents and click the OK Button 7 The Auto Connect Project Dialog Box is displayed online...

Страница 16: ...on the Edit Pane 10 Right click Master and select Display ESI Library 11 The ESI Library Dialog Box is displayed Click the this folder link When the Explorer starts close the dialog box by clicking th...

Страница 17: ...SI Library Dialog Box Click the Button of WAGO_750_354 to confirm that 750 354 000 001 Rev 0x00010002 750 354 000 001 EtherCAT fieldbus coupler device is displayed Confirm that an exclamation mark war...

Страница 18: ...e Node Address If the EtherCAT Tab Page is not displayed on the Edit Pane display it by following step 8 of 7 3 1 Starting the Sysmac Studio and Installing the ESI File A screen is displayed stating G...

Страница 19: ...ts and click the Close Button 7 Cycle the power supply to the Slave Unit 8 The EtherCAT Tab Page is displayed again Right click Master and select Compare and Merge with Actual Network Configuration A...

Страница 20: ...confirmation dialog box is displayed Click the Close Button Node address 1 E001 and 750 354 000 001 Rev 0x00010002 are added to the Network configuration on Sysmac Studio Confirm that the data above a...

Страница 21: ...teps in the EtherCAT Tab Page and confirm that Device name is E001 Device name can be changed as desired Click the Edit Module Configuration Button 3 The Node1 750 354 000 001 E001 Tab Page is display...

Страница 22: ...isplayed on the Edit Pane Confirm that Node1 is displayed in the Position Column and the Slave Unit is displayed To manually set a variable name for the Slave Unit click a column under the Variable Co...

Страница 23: ...default device names are E followed by a serial number that starts from 001 For Slave Units with module configurations the default device names start with an M followed by a sequential number starting...

Страница 24: ...the user program the CPU Unit restarts and communications with the EtherCAT slaves are cut off During that period the slave outputs behave according to the slave settings The time that communications...

Страница 25: ...r Menu 7 Select Synchronization from the Controller Menu 8 The Synchronization Dialog Box is displayed Confirm that the data to transfer NJ501 in the right dialog is selected Then click the Transfer T...

Страница 26: ...No Button Do not return it to RUN mode 10 Confirm that the synchronized data is displayed with the color specified by Synchronized and that a message is displayed stating The synchronization process...

Страница 27: ...progress Inputs and outputs for I O data are in operation EtherCAT NET ERR ERROR Red Not lit There are no errors EtherCAT LINK ACT Link Activity Yellow Flashing Data communications are in progress af...

Страница 28: ...ration If you cannot confirm safety do not proceed to this section after completing until Section 7 4 1 If you proceed to this section make sure to complete all the steps and place the Destination Dev...

Страница 29: ...ue changes to True 7 Confirm that the bit corresponds to the Digital Output Module Slot2 M2 which is connected to the Fieldbus Coupler is turned ON and its LED indicator is lit Digital Output Module S...

Страница 30: ...y not be applicable as described in this document unless you use the devices with the factory default setting 8 1 Initializing the Controller To initialize the settings of the Controller select Clear...

Страница 31: ...9 Revision History 28 9 Revision History Revision code Date of revision Revision reason and revision page 01 Apr 9 2014 First edition...

Страница 32: ...2014 0414 P594 E1 01...

Отзывы: