![Omron V780 Series Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/omron/v780-series/v780-series_user-manual_743948049.webp)
3 - 3
3 Part Names and Functions
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
3-1
Op
eratio
n Ind
icat
ors
3
3-
1-2 Oper
ation
Indicator
s at
S
tartup
Precautions for Correct Use
Refer to
9-1-1 Errors Indicated on Operation Indicators
on page 9-2 for errors indicated by the
operation indicators.
The Reader/Writer will start when you turn ON the power supply. The RUN indicator will flash at 0.1-s
intervals while the Reader/Writer is starting.
IP address conflict detection will operate during Reader/Writer startup.
(If using the BOOTP client is enabled, detection will also operate during BOOTP server quires.)
NORM/
ERR
Green
Lit for 0.2 s
Lights once when processing a communications
command or another command from the host device
is completed normally.
Yellow
Lit for 0.2 s
Flashes once each time an unstable communication
is detected while communications diagnosis is
enabled.
Red
Lit for 0.2 s
Lights once when processing a communications
command or another command from the host device
ends in an error.
Lit
Lit when a major fault has occurred. (Lit when a fatal
error has occurred.)
Flashing at 0.4-s
intervals
Flashes when a minor fault has occurred. (Flashes
when a nonfatal error has occurred.)
Flashing irregularly
twice
Flashes when a minor fault has occurred. (Flashes
when a network error occurs and the IP address
becomes undetermined.)
Cyan
Flashing at 0.1-s
intervals
Flashes during installation location notification.
Flashing once every
3 s
Flashes during operation in the Focus Mode.
---
Not lit
Not lit when the Reader/Writer is on standby.
*1. This indicator flashes from startup until Run Mode or Save Mode is entered and during IP address queries
when BOOTP is enabled.
*2. “During test operation” includes Web browser interface adjustment and execution of utility functions.
3-1-2
Operation Indicators at Startup
Number
and name
Color
Status
Description
The RUN indicator flashes green at 0.1-s intervals.
The LINK/ACT indicator does not light.
LINK/ACT: Not lit.
RUN: Green
Содержание V780 Series
Страница 22: ...Version Upgrade Information 20 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 60: ...3 Part Names and Functions 3 14 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 70: ...4 Installation and Connections 4 10 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 76: ...5 Preparations for Communications 5 6 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 152: ...6 Functions 6 76 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 334: ...8 Browser Interface 8 44 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 358: ...9 Troubleshooting 9 24 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 362: ...10 Maintenance and Inspection 10 4 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 392: ...Appendices A 30 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 393: ...I 1 I UHF RFID System V780 series Reader Writer User s Manual Z389 Index ...
Страница 397: ......