7 - 103
7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-
6 V780 Co
mm
and
Detail
s
7
7-6
-7 Rea
der/W
riter Setting Comman
ds: D
evice Setting
s
Function
This command sets the colors of the NORM/ERR indicators during command execution.
Command Format
*1. To prevent the NORM/ERR indicators from lighting at all during command execution, set all of the lighting
conditions to “Do not flash.” You cannot prevent them from lighting by setting only individual conditions.
7-6-7
Reader/Writer Setting Commands: Device Settings
SET OPERATION INDICATOR CUSTOM CONDITIONS
Byte-0
Byte-1
Byte-2
Byte-3
Byte-4
Byte-5
Byte-6
Byte-7
Byte-8
Byte-9
Byte-10
Byte-11
Transaction identi-
fier
Protocol identifier
Field length
Unit
identifier
Function
code
Register address
Word count
X
X
0000 hex
000D hex
FF hex
10 hex
B800 hex
0003 hex
Byte-12
Byte-13 Byte-14 Byte-15 Byte-16 Byte-17 Byte-18
Byte
count
Color to flash once
for normal com-
mand execution
Color to flash once
for command error
Color to flash once
for unstable com-
munications
06 hex
2 bytes
2 bytes
2 bytes
Parameter
Description
Register address
The register address (B800 hex) that specifies setting operation indicator custom condi-
tions
Word count
The number of words in the operation indicator custom condition settings (0003 hex)
Byte count
The number of bytes in the operation indicator custom condition settings (06 hex)
Color to flash once
for normal com-
mand execution
Specify the color to flash once when V780 command processing ends nor-
mally in 4-digit hexadecimal.
0000 hex: Default
0001 hex: Green
0002 hex: Red
0003 hex: Yellow
0004 hex: Blue
0005 hex: Cyan
0006 hex: Magenta
0007 hex: White
FFFF hex: Do not flash.
*1
0000 hex
Color to flash once
for command error
Specify the color to flash once when V780 command processing ends in an
error in 4-digit hexadecimal.
*The color settings are they same as for flashing once for normal command
completion, given above.
0002 hex
Color to flash once
for unstable com-
munications
Specify the color to flash once when the results of executing communica-
tions diagnostics indicates that communications are unstable in 4-digit hexa-
decimal.
*The colors settings are they same as for flashing once for normal command
completion, given above.
0003 hex
Содержание V780 Series
Страница 22: ...Version Upgrade Information 20 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 60: ...3 Part Names and Functions 3 14 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 70: ...4 Installation and Connections 4 10 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 76: ...5 Preparations for Communications 5 6 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 152: ...6 Functions 6 76 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 334: ...8 Browser Interface 8 44 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 358: ...9 Troubleshooting 9 24 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 362: ...10 Maintenance and Inspection 10 4 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 392: ...Appendices A 30 UHF RFID System V780 series Reader Writer User s Manual Z389 ...
Страница 393: ...I 1 I UHF RFID System V780 series Reader Writer User s Manual Z389 Index ...
Страница 397: ......