Executing Other Commands (such as SET READER/WRITER and
GET READER/WRITER INFORMATION)
1. The command code, command parameters, and command data are set from the PLC while the READY sig-
nal is ON. The value of the update counter response is matched with the value of the Update counter in the
V780 response area.
2. The user (PLC) turns ON the EXE signal. This tells the Reader/Writer to start execution.
3. When the Reader/Writer receives the instruction to start execution, it turns OFF the READY signal and turns
ON the BUSY signal.
4. When the processing at the Reader/Writer side ends normally, the Reader/Writer sets the error code,
response information, and response data, adds 1 (increments) to the update counter value, and then turns
ON the NORM signal. Moreover, the Reader/Writer turns OFF the BUSY signal.
5. The user (PLC) detects a change in the update counter value, confirms that the NORM signal has turned
ON, and acquires the response data. After the acquisition of data, the user (PLC) updates the update
counter response value in accordance with the value of the Update counter in the V780 response area, and
turns OFF the EXE signal. This tells the Reader/Writer to stop execution.
6. When the Reader/Writer receives the instruction to stop execution, it turns OFF the NORM signal and turns
ON the READY signal.
7. When the processing at the Reader/Writer side ends in an error, the Reader/Writer sets the error code and
response information, and turns ON the ERR signal. At this time too, the Reader/Writer adds 1 (increments)
to the update counter value. And also turns OFF the BUSY signal.
8. The user (PLC) detects a change in the update counter value, confirms that the ERR signal has turned ON,
acquires the error code and response information, and then checks the error contents. After checking, the
user (PLC) updates the update counter response value in accordance with the value of the Update counter
in the V780 response area, and turns OFF the EXE signal. This tells the Reader/Writer to stop execution.
9. When the Reader/Writer receives the instruction to stop execution, it turns OFF the ERR signal and turns ON
the READY signal.
EXE
READY
BUSY
NORM
ERR
1 2 3
4
5
7
6
8
9
0000 hex
0001 hex
0000 hex
0001 hex
0000 hex
0001 hex
0000 hex
0001 hex
0000 hex
EXE
Command code
Command
parameters
Command data
READY
BUSY
NORM
ERR
Error code
Response
information
Response data
Command
Area
Response
Area
Update counter
response
Update counter
Содержание V780-HMD68-EIP-JP
Страница 14: ...Manual Structure 12 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 36: ...2 System Configuration 2 6 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 52: ...3 Part Names and Functions 3 16 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 62: ...4 Installation and Connections 4 10 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 152: ...6 Functions 6 80 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 236: ...7 Ethernet IP Communications 7 84 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 282: ...8 Browser Interface 8 46 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 308: ...10 Maintenance and Inspection 10 4 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 321: ...I 1 I UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 Index ...
Страница 324: ...I 4 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 Index ...
Страница 325: ......