Function
This command sets the RF Tag selection filter conditions for the Reader/Writer.
z
Command Area
z
Response Area
SET RF TAG SELECTION FILTER CONDITIONS
Signal/data
Data type
Size
Function
CmdCode/Command Code
WORD
2 bytes
300B hex
CmdParam1/Command Parameter 1
WORD
2 bytes
0000 hex (Not used.)
CmdParam2/Command Parameter 2
WORD
2 bytes
0000 hex (Not used.)
Reserved/Reserved Area
WORD
2 bytes
0000 hex (Not used.)
Cnt Response/Update Counter
Response
WORD
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to
CmdData/Command Data
RF Tag selec-
tion
filter conditions
Enable/dis-
able
WORD
2 bytes
Specifies whether to enable or disable RF Tag
selection filter conditions.
0000 hex: Disable
0001 hex: Enable
Default setting: 0000 hex
Address
*1
*1. If the RF Tag selection filter conditions settings are disabled, this value is always 0000 hex.
WORD
2 bytes
Specifies the address (in words) of the RF Tag to check.
1000 to 17FF hex: UII (EPC) area
*2
2000 to 27FF hex: TID area
3000 to 3FFF hex: User area
* You cannot specify 0000 to 07FF hex
(reserved area).
Default setting: 0000 hex
*2. Address 1000 hex specifies the "UII (EPC)_CRC-16" area of the RF Tag. Since this area varies depending on
the EPC code, care must be taken during use.
Data
length
*1
WORD
2 bytes
Specifies the number of words of data to check.
Setting range: 0000 to 0010 hex
Default setting: 0000 hex
Data
*1
ARRAY[]
OF WORD
16 words
(32 bytes)
Specifies the data to check. (16 words)
* Fill unused data with 0000 hex.
* In compliance with Gen2 standards, bits 0
to 255 are masked, so the last bit of word
16 (bit 256) is ignored.
Default setting: 00..00 hex
Signal/data
Data type
Size
Function
ErrCode/Command Code
WORD
2 bytes
Error code
RespInfo1/Response Information 1
WORD
2 bytes
0000 hex (Not used.)
RespInfo2/Response Information 2
WORD
2 bytes
0000 hex (Not used.)
RespInfo3/Response Information 3
WORD
2 bytes
0000 hex (Not used.)
Cnt/Update Counter
WORD
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to
Содержание V780-HMD68-EIP-JP
Страница 14: ...Manual Structure 12 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 36: ...2 System Configuration 2 6 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 52: ...3 Part Names and Functions 3 16 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 62: ...4 Installation and Connections 4 10 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 152: ...6 Functions 6 80 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 236: ...7 Ethernet IP Communications 7 84 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 282: ...8 Browser Interface 8 46 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 308: ...10 Maintenance and Inspection 10 4 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 ...
Страница 321: ...I 1 I UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 Index ...
Страница 324: ...I 4 UHF RFID System V780 series Reader Writer User s Manual EtherNet IPTM Z402 Index ...
Страница 325: ......