53
V700-L11
User's Manual
Secti
on 6
6
.2 Sp
aci
ng
f
o
r i
n
st
al
ling
ID
RW he
ads
Section 6
Performance Data Based on Operating Conditions (information only)
6.2 Spacing for installing IDRW heads
When two or more IDRW heads are connected via link unit, there is no limitation on the spacing of antenna
sections since all the IDRW heads do not handle a command simultaneously.
If IDRW heads are connected to an individual upstream controller, and when these IDRW heads situated in
close vicinity are simultaneously processing a command, mutual interference can occur across the IDRW
heads, possibly leading to total inability of communication or loss in effective communication distance despite
presence of tags. To avoid such a problem, be sure to install the antenna sections at the intervals specified
below.
■
Model V700-HMD13
■
Model V700-HMD11-1
➀
Side-by-side configuration
➁
Face-to-face configuration
1000 mm or greater
1000 mm or greater
1000 mm or greater
410 mm or greater
410 mm or greater 410 mm or greater
460 mm or greater
460 mm or greater