29
V700-L11
User's Manual
Section 2
2.
3 ID link
uni
t:
M
o
de
l V70
0
-L11
Section 2
Unit Specifications
■
How to connect cables
➀
Fit a compression ring to the stripped section of each cable.
Next, being sure of the connector orientation, insert each cable into a corresponding hole on the
connector.
➁
Securely fasten each cable using the cable locking screw on the connector.
An ordinary screwdriver whose shank is tapered at the tip does not go all the way into the hole. Use
a miniature flat-blade screwdriver with a straight shank.
Tighten the cable locking screws at an appropriated tightening torque (approx. 0.5 N-m).
➂
Connect the connector to the link unit together with the cables.
Match the orientation of link unit side connector with that of cable side connector, insert the cable
side connector all the way, and then tighten the connector lock screws.
➃
When removing the connector, fully loosen the two lock screws and draw out it straight by holding
the protrusions on connector. If the connector does not easily come loose, draw it out while holding
down the link unit proper.
Miniature flat-blade screw
driver with straight shank
The following purpose-built screwdriver is available:
OMRON: Model XW4Z-00C
Form of tip
0.6 mm
Front view
Side view
3.5 mm
Lock screws