35
Heat-resistive RFID System
User's Manual
Se
c
tion 2
RS
-4
8
5
Inte
rf
a
c
e
Conne
c
tion
(
V
6
8
0
-CA2
D)
Section 2
Installation, Connections, and Wiring
Connecting and Disconnecting the Connector
1.
Attach the crimp terminals to the sections of the cable where the sheath has been stripped.
Make sure the connector is facing the right direction and insert each wire into the correct connector hole.
2.
Securely tighten the connector's cable fixing screws for each wire.
Use a small flat-blade screwdriver with a uniform thickness. Do not use a standard screwdriver with a tapered end only. Other-
wise, the screwdriver will not fully insert into the hole.
Tighten the cable fixing screws to a suitable torque of approximately 0.5 N·m.
Small flat-blade screwdriver
with a tip of uniform thickness.
Side
Front
0.6 mm
3.5 mm
The following screwdriver is available.
OMRON: XW4Z-00C
End shape