36
Sec
tion
3
Ex
planat
ion of
Rea
d
ing Syst
em
V500-R2 series
User’s Manual
Section 3
Function Explanation
Explanation of Reading System
There are following reading systems for this bar code reader.
Setting method p.69
*1
Effective duration of reading
When the trigger input method is external trigger signal effective duration designation system or RS-232C
command, effective duration setting is required beforehand.
Effective duration setting method p.75
Reading system
Trigger reading
Full-time reading
Reading starts by applying reading trigger
from outside.
This system is mainly used when operation.
During the power is turned on, laser is
radiated all the time, to be able to read
any time. This system is mainly used at
installation and system testing.
Trigger
Input method
External
trigger
signal
When the external trigger signal is turned
on, laser radiates and starts reading. The
"Trigger controlled system" reads during
the trigger is ON, and the "Effective
duration designation system" reads only the
effective duration (*1) which is set
beforehand after the trigger is ON.
–
(Ignored even when input.)
RS-232C
command
The upper equipment sends the
communication command and the laser
beam radiates to start reading. After
receiving the command, it reads only for the
effective duration (*1) which is set
beforehand.
–
(Ignored even when input.)
SCAN
button
(Back side)
Press the SCAN button once to read once.
Handy to use to check if the reading
condition setting is appropriate.
–
(Ignored even when pressed.)
Reading
operation
Single
reading
When the reading succeeds, the data is
output and ends reading automatically.
Reads continuously and outputs the data
continuously.
Plural
reading
Reads bar codes continuously during the
trigger is ON or effective duration (*1).
When the first reading is completed, data is
once output and while reading the same
bar codes continuously, no output is made.
Outputs newly only when the data differ
from the adjacent bar code.
The bar code reading continues in series.
While reading the same bar code, output
is not newly made. Outputs newly only
when the data differ from the adjacent bar
code.
Continuous
reading
Reads bar codes continuously during the
trigger is ON or effective duration (*1).
Outputs data continuously even for the
same bar code.
Reads continuously and outputs the data
continuously.
Содержание V500-R2 Series
Страница 1: ...Z334 E1 01A Cat No Fixed Laser Type Barcode Reader User s Manual V500 R2 Series...
Страница 18: ...16 V500 R2 series User s Manual Introduction Contents Introduction MEMO...
Страница 36: ...34 Section 2 Installation V500 R2 series User s Manual Section 2 Wiring and Installation MEMO...
Страница 52: ...50 Section 3 Test Reading Function V500 R2 series User s Manual Section 3 Function Explanation MEMO...
Страница 143: ......