31
V500-R2 series
User’s Manual
Section
2
Wi
ri
ng
Section 2
Wiring and Installation
When you make a connection cable, use the following connectors.
Recommended parts for the connector
Power supply
Recommended parts for the power supply
Input/output circuit
Input circuit for the external trigger signal (V500-R2 series)
Usage
Manufacturer
Model
For cable relay
Hosiden Corporation
TCS8587-0170477
For panel installation 2
Hosiden Corporation
TCS1080-0120177
Logic of external trigger signal can be selected.
You can select the output logic of READ OK and READ NG signal.
Manufacturer
Model
OMRON Corporation
S8VS-01505
Item
Minimum
value
Maximum
value
Terminal voltage Von when a
transistor is turned on
0 V
0.8 V
Terminal voltage Voff when a
transistor is turned off
2.0 V
3.3 V
Setting method p.57
Trigger ON
Trigger ON
Positive logic
(HIGH active)
Negative logic
(LOW active)
Von/off
TRIG
SG
Vcc
Internal
circuit
External trigger signal