Tilt angle
Generally, a tilt angle is not specified, because it differs according to the bar code
height.
Scan all the bar code with the laser.
Curvature
In case of the following conditions, the bar code of 8-digit EAN, curvature range 15 mm
or more and 13-digit EAN, curvature range 20 mm or more can be read.
• Bar code:
Resolution = 0.26 mm, EAN, PCS = 0.9
• Reading distance:
110 mm from the case end
• Installation condition: Pitch angle
α
= 0°, skew angle
β
= 15°, tilt angle
γ