Example 12
Purpose:
To print PC data and the time of data transfer
MOV
#0002
101
10001
MOV
#0100
102
PC Program
ASCII Unit Program
Start
10300
ASCII busy
WRITE flag
10
OPEN #2,“LPRT:(47)”
20
PC READ “2I4”;D1,D2
30
PRINT #2,“DATA1 = “;D1,
“DATA2=“;D2,”TIME= “;TIME$
40
GOTO 20
Remarks:
PC data and the time of transfer are output to a printer connected to port 2 of
the ASCII Unit. The PC read statement is used to obtain the data from the
PC.
Output:
DATA1 = 5678
DATA1 = 3249
DATA2 = 9876
DATA2 = 12
TIME = 13:45:03
TIME = I4:02:51
Example 13
Purpose:
To display the state of PC bit 1000 on a display device con-
nected to port 2
•
This example does not require a PC data transfer routine.
Example Programs
Section 6-1