Appendix C
PC Statements and Refresh Timing
123
PC OFF
After the ON PC GOSUB statement is executed, the PC’s interrupt number is written in. If the PC OFF state-
ment is subsequently executed, then even if the Write flag is set, the GOSUB statement will not be executed
and the ASCII busy flag will not be set.
I/O refresh
I/O refresh
I/O refresh
Instruction execution
Instruction execution
Instruction execution
ASCII Unit
C200H CPU
I/O refresh
ON PC GOSUB statement execution
ON PC GOSUB statement execution
Interrupt number
(word n bits 04 through 07)
WRITE flag (word n bit 01)
ASCII Unit (word n+3 bit 00)