![Omron SYSDRIVE 3G3MX-A2002 Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/omron/sysdrive-3g3mx-a2002/sysdrive-3g3mx-a2002_user-manual_742838170.webp)
4-79
4-2 Function Mode
4
Functions
002Ah
2nd deceleration time 1
F203
(HIGH)
R/W
0 to 300000
*2
0.01 [s]
002Bh
F203
(LOW)
R/W
002Ch
Operator rotation direction
selection
F004
R/W
0: Forward
1: Reverse
002Dh
Frequency reference
selection
A001
R/W
0: Digital Operator (volume)
1: Terminal
2: Digital Operator
3: ModBus communication
002Eh
RUN command selection
A002
R/W
1: Terminal
2: Digital Operator
3: ModBus communication
002Fh
Base frequency
A003
R/W
30 to Max. frequency
1. [Hz]
0030h
2nd base frequency
A203
R/W
30 to 2nd max. frequency
1. [Hz]
0031h
Maximum frequency
A004
R/W
30 to 400
1. [Hz]
0032h
2nd maximum frequency
A204
R/W
30 to 400
1. [Hz]
0033h
FV/FI selection
A005
R/W
0: FV/FI
1: Disabled
2: FV/VR
3: FI/VR
0034h
FV start frequency
A011
R/W
0 to Max. frequency
0.1 [Hz]
0035h
FV end frequency
A012
R/W
0 to Max. frequency
0.1 [Hz]
0036h
FV start ratio
A013
R/W
0 to 100
1. [%]
0037h
FV end ratio
A014
R/W
0 to 100
1. [%]
0038h
FV start selection
A015
R/W
0: External start frequency
1: 0 Hz
0039h
FV, FI sampling
A016
R/W
1 to 8
1
003Ah
Multi-step speed
reference 0
A020
R/W
0/Starting frequency to Max. frequency
0.1 [Hz]
003Bh
2nd multi-step speed
reference 0
A220
R/W
0/Starting frequency to 2nd max.
frequency
0.1 [Hz]
003Ch
Multi-step speed
reference 1
A021
R/W
0/Starting frequency to Max. frequency
0.1 [Hz]
003Dh
Multi-step speed
reference 2
A022
R/W
0/Starting frequency to Max. frequency
0.1 [Hz]
003Eh
Multi-step speed
reference 3
A023
R/W
0/Starting frequency to Max. frequency
0.1 [Hz]
003Fh
Multi-step speed
reference 4
A024
R/W
0/Starting frequency to Max. frequency
0.1 [Hz]
0040h
Multi-step speed
reference 5
A025
R/W
0/Starting frequency to Max. frequency
0.1 [Hz]
Register
No.
Function name
Parameter
No.
R/W
function
Data
Resolution
*1. The Inverter's rated current is "1000".
*2. The second decimal place is ignored when the value is over 10000 (100.0 seconds).
Содержание SYSDRIVE 3G3MX-A2002
Страница 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Страница 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Страница 24: ......
Страница 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Страница 90: ......
Страница 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Страница 180: ......
Страница 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Страница 188: ......
Страница 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Страница 205: ...7 8 7 4 Dimensional Drawing 7 Specifications 7 4 Dimensional Drawing 3G3MX A2002 AE002 120 110 67 5 6 5 103 2 6 7 80...
Страница 208: ...7 11 7 4 Dimensional Drawing 7 Specifications 3G3MX A4004 AE007 139 2 6 7 98 118 4 130 2 5 110 5...
Страница 210: ...7 13 7 4 Dimensional Drawing 7 Specifications 3G3MX A2055 A2075 A4055 A4075 205 220 6 5 6 164 180 2 6 7 155 5 5...
Страница 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Страница 223: ...7 26 7 5 Options 7 Specifications 3G3AX EFI25 L3 T S R L1 L2 10 2 260 MIN 205 235 308 5 331 355 160 40 60 164 182...
Страница 230: ......
Страница 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Страница 249: ...INDEX...
Страница 252: ......