No.16S121-03
59/64
STC-MBS891U3V / STC-MCS891U3V / STC-MBS123BU3V / STC-MCS123BU3V
Product Specifications and Use’s Guide
Name
Description
PayloadSize
Provides the number of bytes transferred for each image or chunk on the stream
channel. This includes any end-of-line, end-of-frame statistics or other stamp data. This
is the total size of data payload for a data block.
Name
Description
LineSelector
Selects the physical line (or pin) of the external device connector to configure.
LineMode
Controls if the physical Line is used to Input or Output a signal.
LineInverter
Controls the inversion of the signal of the selected input or output Line.
LineStatus
Returns the current status of the selected input or output Line.
LineSource
Selects which internal acquisition or I/O source signal to output on the selected Line.
LineMode must be Output.
UserOutputSelector
Selects which bit of the User Output register will be set by UserOutputValue.
UserOutputValue
Sets the value of the bit selected by UserOutputSelector.
StrobeOutDelay
Delay of StrobeOut signal when LineSource is set to StrobeOut(us).
StrobeOutOnTime
Duration of StrobeOut signal when LineSource is set to StrobeOut(us).
TriggerOutDelay
Delay of TriggerOut signal when LineSource is set to TriggerOut(us).
TriggerOutOnTime
Duration of TriggerOut signal when LineSource is set to TriggerOut(us).
LineDeviceResetMode
Sets the Line device reset mode.
LineDebounceTime
Sets the value of the input line debouncer time.
Name
Description
CounterSelector
Selects which Counter to configure.
CounterEventSource
Select the events that will be the source to increment the Counter.
CounterEventActivation
Selects the Activation mode Event Source signal.
CounterResetSource
Selects the signals that will be the source to reset the Counter.
CounterResetActivation
Selects the Activation mode of the Counter Reset Source signal.
CounterReset
Does a software reset of the selected Counter and starts it. The counter starts counting
events immediately after the reset unless a Counter trigger is active. CounterReset can
be used to reset the Counter independently from the CounterResetSource. To disable
the counter temporarily, set CounterEventSource to Off.
CounterValue
Reads or writes the current value of the selected Counter.
CounterValueAtReset
Reads the value of the selected Counter when it was reset by a trigger or by an explicit
CounterReset command.
CounterDuration
Sets the duration (or number of events) before the CounterEnd event is generated.
CounterStatus
Returns the current status of the Counter.
CounterTriggerSource
Selects the source to start the Counter.
CounterTriggerActivation
Selects the activation mode of the trigger to start the Counter.