No.16S121-03
51/64
STC-MBS891U3V / STC-MCS891U3V / STC-MBS123BU3V / STC-MCS123BU3V
Product Specifications and Use’s Guide
9.11
Save and load the camera settings
The camera has the camera setting save function, the camera setting including factory default loads function.
The camera has below two camera settings.
Default: The factory default settings (This setting cannot change)
User Set X: Over writeable camera settings (X: 0 to 7)
These camera settings load from ROM to the register in the RAM on the camera and camera settings save to ROM.
The camera settings saving and loading is controllable with Parameters (User Set Selector, User Set Default), and
commands (UserSetLoad, UserSetSave) in UserSetControl category of GenICam.
The details of the parameters and the functions are in the table below:
GenICam Parameters
UserSetSelector
IEnumeration Type
Select “Default” or ”UserSet X”
UserSetLoad or UserSetSave process for the selected settings.
UserSetLoad
ICommand Type
The camera settings load from ROM to the register in RAM.
UserSetSave
ICommand Type
The camera settings at the register in RAM save to ROM.
UserSetDefault
IEnumeration Type
Select which settings (“Default or UserSet X) load automatically when the
camera power is on. This selection saves automatically.
Setting Procedure
1. Selects “UserSetX” at “UserSetSelector”
2. Execute “UserSetSave”
When UserSetSave is executing,
the camera settings at the register in RAM
are saved to the ROM that is selected at
UserSetSelector.
Caution:
UserSetSave cannot execute when “Default”
was selected at “UserSet Selector”
ROM
UserSetX
ROM
Default
Camera
Setting
UserSetSelector
Selector